Grant: Travel Awards - Institute Community Support
University of Toronto
$1,500.00
Microfabricated microporous membranes prolong the functional lifetime of a closed-loop insulin delivery implant in a type I diabetic rat model by passively modulating the host immune response
FY 2014-15
Summary
Objective:
Closed-loop insulin delivery systems offer diabetic patients improved glycemic control, compliance and quality of life, however long-term efficacy has yet to be demonstrated due to poor device biocompatibility. Sustained administration of anti-inflammatory agents may improve device lifetime, however such strategies are accompanied with side-effects and difficult to implement. We demonstrate prolonged functional lifetime of a chemically-driven closed-loop insulin delivery implant by passively impeding cell migration to the implant surface using a microfabricated microporous membrane.
Methods:
Polymeric membranes featuring micron-sized pores were constructed using soft-lithography and affixed overtop of a chemically-driven closed-loop insulin delivery system comprised of an insulin reservoir sealed with a variable-porosity glucose-responsive albumin plug. Devices with and without the microporous membrane were implanted subcutaneously in healthy rats and assessed for tissue biocompatibility over 30 days. Device efficacy was assessed in a diabetic rat model. Blood insulin, glucose, and c-peptide levels were measured for 30 days.
Result:
Microporous membranes minimized accumulation of cells at the glucose-responsive plug surface and subsequent cell-mediated degradation compared to unprotected devices. The membranes further resulted in resolution of the inflammatory process to the implant as evidenced by minimal residual perivascular lymphocytic and histocytic inflammation, absence of neutrophils at the implant site, and a thinner fibrous capsule by day 30 following implantation. Finally, use of the microporous membranes successfully prolonged the in vivo efficacy duration by up to 3-fold (28 days) compared to unprotected devices.
Conclusion:
Microfabricated microporous membranes act as a barrier to cell migration to the immunogenic surface of a chemically driven closed-loop insulin delivery device, thereby improving implant lifetime.
Department
Program
Travel Awards - Institute Community Support
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
CIHR Funding Decisions Database
As published
Id
315391
Name
Li Jason
Region
Ontario
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Nutrition, Metabolism and Diabetes
Theme2
Biomedical
Prcname2
Institute of Nutrition, Metabolism and Diabetes
Projecttitle
Microfabricated microporous membranes prolong the functional lifetime of a closed-loop insulin delivery implant in a type I diabetic rat model by passively modulating the host immune response
Programtype2
Undefined
Orgnameinp2
University of Toronto
Cihramount2
$1,500
Cihrequipment2
$0
Programname2
Travel Awards - Institute Community Support
Keyworddelim
Closed Loop Insulin Delivery; Implant Biocompatability; Implantable Device; Insulin Delivery; Responsive Polymer; Type I Diabetes
Abstract
Objective:
Closed-loop insulin delivery systems offer diabetic patients improved glycemic control, compliance and quality of life, however long-term efficacy has yet to be demonstrated due to poor device biocompatibility. Sustained administration of anti-inflammatory agents may improve device lifetime, however such strategies are accompanied with side-effects and difficult to implement. We demonstrate prolonged functional lifetime of a chemically-driven closed-loop insulin delivery implant by passively impeding cell migration to the implant surface using a microfabricated microporous membrane.
Methods:
Polymeric membranes featuring micron-sized pores were constructed using soft-lithography and affixed overtop of a chemically-driven closed-loop insulin delivery system comprised of an insulin reservoir sealed with a variable-porosity glucose-responsive albumin plug. Devices with and without the microporous membrane were implanted subcutaneously in healthy rats and assessed for tissue biocompatibility over 30 days. Device efficacy was assessed in a diabetic rat model. Blood insulin, glucose, and c-peptide levels were measured for 30 days.
Result:
Microporous membranes minimized accumulation of cells at the glucose-responsive plug surface and subsequent cell-mediated degradation compared to unprotected devices. The membranes further resulted in resolution of the inflammatory process to the implant as evidenced by minimal residual perivascular lymphocytic and histocytic inflammation, absence of neutrophils at the implant site, and a thinner fibrous capsule by day 30 following implantation. Finally, use of the microporous membranes successfully prolonged the in vivo efficacy duration by up to 3-fold (28 days) compared to unprotected devices.
Conclusion:
Microfabricated microporous membranes act as a barrier to cell migration to the immunogenic surface of a chemically driven closed-loop insulin delivery device, thereby improving implant lifetime.
Competitiondate
201409
Approvedterm2
1 yr 0 mth
Pinamesdelim
Li, Jason
Approvedterm
1 an 0 mois
Cihrcontribution2
Inst of Nutr Metabolism &Diab~ $1,500~ $0~