Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments - Category 1 (<$150,000)

University of Toronto

$118,164.00

A polscope for non-invasive visualization of meiotic spindle

FY 2008-09

Summary
This application is for a polscope to support our research on autonomous microrobotic cell manipulation. Without using invasive, exogenous stains or labels, the polscope uses circularly polarized light combined with electro optical hardware to achieve orientation-independent, non-invasive visualization of intracellular structures in real time, such as the meiotic spindle within mammalian oocytes/embryos. For gene and molecular target screening in genetics, reproduction, and developmental biology, the reliable injection of thousands of mouse oocytes/zygotes needs to be conducted. The low speed and poor success rates of manual injection seriously hamper large-scale gene and molecular target screening. Aiming to improve the pregnancy rate in state-of-the-art assisted reproduction technologies, our on-going collaborative research involves the development of a first-of-its-kind, fully automated microrobotic mouse zygote injection system and the application of the automated system to screening for mitochondrial proteins that regulate embryonic developmental competence. The meiotic spindle is crucial for normal chromosome alignment and separation of maternal chromosomes during meiosis of embryo development. It is important to visualize and position the meiotic spindle away from the penetration site, which will reduce spindle damage/dysfunction and increase microinjection success rates. The capability of real-time, accurate, non-invasive visualization of the meiotic spindle with the polscope, together with the high reproducibility and the optimization of operation parameters, the fully automated microrobotic system will be capable of injecting 15-20 mouse zygotes/minute (vs. ~5/min by a highly experienced technician) with a success rate higher than 75% (vs. 30-40% in manual injection) to significantly facilitate large-scale molecule screening in assisted reproduction as well as in genetics.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
358937-2008
Name nom
Sun, Yu
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2008
Competition year année de concours
2008
Award amount
118164
Program id
EQPEQ
Program nane en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1053
Committee name en
Mechanical Engineering - A
Committee name fr
Génie mécanique - A
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
A polscope for non-invasive visualization of meiotic spindle
Keyword
NA
Application summary
This application is for a polscope to support our research on autonomous microrobotic cell manipulation. Without using invasive, exogenous stains or labels, the polscope uses circularly polarized light combined with electro optical hardware to achieve orientation-independent, non-invasive visualization of intracellular structures in real time, such as the meiotic spindle within mammalian oocytes/embryos. For gene and molecular target screening in genetics, reproduction, and developmental biology, the reliable injection of thousands of mouse oocytes/zygotes needs to be conducted. The low speed and poor success rates of manual injection seriously hamper large-scale gene and molecular target screening. Aiming to improve the pregnancy rate in state-of-the-art assisted reproduction technologies, our on-going collaborative research involves the development of a first-of-its-kind, fully automated microrobotic mouse zygote injection system and the application of the automated system to screening for mitochondrial proteins that regulate embryonic developmental competence. The meiotic spindle is crucial for normal chromosome alignment and separation of maternal chromosomes during meiosis of embryo development. It is important to visualize and position the meiotic spindle away from the penetration site, which will reduce spindle damage/dysfunction and increase microinjection success rates. The capability of real-time, accurate, non-invasive visualization of the meiotic spindle with the polscope, together with the high reproducibility and the optimization of operation parameters, the fully automated microrobotic system will be capable of injecting 15-20 mouse zygotes/minute (vs. ~5/min by a highly experienced technician) with a success rate higher than 75% (vs. 30-40% in manual injection) to significantly facilitate large-scale molecule screening in assisted reproduction as well as in genetics.