Grant: Discovery Grants Program - Individual
Université Laval
$29,000.00
A scintillator based radiation detector for three-dimensional dose measurements in radiotherapy
FY 2012-13
Summary
Today, nearly all radiation treatments of curative intent aims to deliver a dose of radiation to the exact three-dimensional shape of tumors. This high treatment conformity means that tumors can receive higher doses (more chance of treatment success) while normal tissues receive lower doses (less risk of complication). However, to make sure that conformal treatments really translate into better clinical outcomes it is necessary to do regular verifications by performing sets of measurements.
We intend to design a new type of radiation detector system to rapidly and accurately map whole three-dimensional (3D) radiation dose distributions. This device will be useful to measure complex dose distributions to make sure that the radiation dose planned is the radiation dose delivered. Right now, the vast majority of dose detectors can either measure dose at a point or dose in a 2D plane.
Our approach is based on plastic scintillator, an organic material that emits light when irradiated. The emission is nearly instantaneous and proportional to the dose. This means that each time a radiation beam hits the detector system it will generate a light pattern of the exact shape of the dose distribution. Because the density and chemical composition of the scintillator are close to that of human tissues, the passage of radiation through the scintillator will mimic the passage of radiation through a human body. By placing light sensors at the periphery of the scintillator we will collect information about the light distribution and use specialized algorithms to reconstruct the 3D dose information.
Program
Discovery Grants Program - Individual
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
385773-2010
Name nom
Archambault, Louis
Department département
Physique, génie physique et optique
Organization id
51
Institution établissement
Université Laval
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2010
Award amount
29000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
3
Nb partie
3
Application title
A scintillator based radiation detector for three-dimensional dose measurements in radiotherapy
Keyword
NSERC
Application summary
Today, nearly all radiation treatments of curative intent aims to deliver a dose of radiation to the exact three-dimensional shape of tumors. This high treatment conformity means that tumors can receive higher doses (more chance of treatment success) while normal tissues receive lower doses (less risk of complication). However, to make sure that conformal treatments really translate into better clinical outcomes it is necessary to do regular verifications by performing sets of measurements.
We intend to design a new type of radiation detector system to rapidly and accurately map whole three-dimensional (3D) radiation dose distributions. This device will be useful to measure complex dose distributions to make sure that the radiation dose planned is the radiation dose delivered. Right now, the vast majority of dose detectors can either measure dose at a point or dose in a 2D plane.
Our approach is based on plastic scintillator, an organic material that emits light when irradiated. The emission is nearly instantaneous and proportional to the dose. This means that each time a radiation beam hits the detector system it will generate a light pattern of the exact shape of the dose distribution. Because the density and chemical composition of the scintillator are close to that of human tissues, the passage of radiation through the scintillator will mimic the passage of radiation through a human body. By placing light sensors at the periphery of the scintillator we will collect information about the light distribution and use specialized algorithms to reconstruct the 3D dose information.