Grant: Discovery Grants Program - Individual
Université de Sherbrooke
$31,000.00
Artificial intelligence, signal and data processing towards greater end-user flexibility through increased sensitivity and detection efficiency in PET imaging
FY 2019-20
Summary
This proposal is part of a novel vision where digital signal and data processing, artificial intelligence and distributed modular analysis can substantially improve both the intrinsic performance and end-user flexibility of Positron Emission Tomography (PET), a vision symbiotic and interdependent on the usual advances in technology, comprehension of system-level issues and socio-economic efficiency constraints. In the short term, the research program will mitigate the pressure on the flexibility paradigm emerging as side-effects of other resolution, TOF and detector breakthroughs. In the mid to long term, the vision will uniquely benefit all PET end-users through innovative complements to existing technology, helping this molecular and genomic imaging modality continue to grow in the next decades through the emergence of new radiotracers or new routine care and research protocols.*** *Depending on scanner performance like resolution, contrast and sensitivity, the end-user faces a significant trade-off between image quality, injected dose and scan length, directly impacting the flexibility, scientific return and cost/benefit ratio of any given imaging protocol, all of primordial importance in the continued availability of the modality in healthcare worldwide. Some new protocols will require high sensitivity, others good contrast and resolution, or both: the cost effective evolution of PET requires flexibility, which an all-digital architecture and the aforementioned vision inherently provide.*** *The program focuses on sensitivity and detection efficiency because, when considering the above end-user trade-off, these are currently the most under-studied and wide-reaching factors through which end-user flexibility can be gained quickly. Varied interwoven aspects of PET technology will immediately benefit from the proposed vision: 1) optimization of a novel artificial intelligence method I recently demonstrated to improve detection efficiency by 50 to 200%; 2) refinement of image reconstruction methods to account for the improved efficiency, minimizing its impact on image quality; 3a) algorithmic maximization of new SPAD detectors' dynamic range to improve sensitivity; 3b) implementation of the new algorithms in modular embedded power as a 3D ASIC affixed to the detector itself instead of a central computer; and 4) design of an advanced stereoscopic DOI technique to decrease localization uncertainties and gain both contrast and efficiency.*** *Overall this vision will lead to new scientific if not commercial endeavors, allowing adaptations of digital techniques and artificial intelligence mostly unheard of in PET until now to circumvent many known problems and limitations and to open new possibilities for the modality.
Program
Discovery Grants Program - Individual
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2016-05036
Name nom
Michaud, JeanBaptiste
Department département
Génie électrique et génie informatique
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2016
Award amount
31000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Installment
inst:4 - 5
Partie
4
Nb partie
5
Application title
Artificial intelligence, signal and data processing towards greater end-user flexibility through increased sensitivity and detection efficiency in PET imaging
Keyword
NSERC
Application summary
This proposal is part of a novel vision where digital signal and data processing, artificial intelligence and distributed modular analysis can substantially improve both the intrinsic performance and end-user flexibility of Positron Emission Tomography (PET), a vision symbiotic and interdependent on the usual advances in technology, comprehension of system-level issues and socio-economic efficiency constraints. In the short term, the research program will mitigate the pressure on the flexibility paradigm emerging as side-effects of other resolution, TOF and detector breakthroughs. In the mid to long term, the vision will uniquely benefit all PET end-users through innovative complements to existing technology, helping this molecular and genomic imaging modality continue to grow in the next decades through the emergence of new radiotracers or new routine care and research protocols.*** *Depending on scanner performance like resolution, contrast and sensitivity, the end-user faces a significant trade-off between image quality, injected dose and scan length, directly impacting the flexibility, scientific return and cost/benefit ratio of any given imaging protocol, all of primordial importance in the continued availability of the modality in healthcare worldwide. Some new protocols will require high sensitivity, others good contrast and resolution, or both: the cost effective evolution of PET requires flexibility, which an all-digital architecture and the aforementioned vision inherently provide.*** *The program focuses on sensitivity and detection efficiency because, when considering the above end-user trade-off, these are currently the most under-studied and wide-reaching factors through which end-user flexibility can be gained quickly. Varied interwoven aspects of PET technology will immediately benefit from the proposed vision: 1) optimization of a novel artificial intelligence method I recently demonstrated to improve detection efficiency by 50 to 200%; 2) refinement of image reconstruction methods to account for the improved efficiency, minimizing its impact on image quality; 3a) algorithmic maximization of new SPAD detectors' dynamic range to improve sensitivity; 3b) implementation of the new algorithms in modular embedded power as a 3D ASIC affixed to the detector itself instead of a central computer; and 4) design of an advanced stereoscopic DOI technique to decrease localization uncertainties and gain both contrast and efficiency.*** *Overall this vision will lead to new scientific if not commercial endeavors, allowing adaptations of digital techniques and artificial intelligence mostly unheard of in PET until now to circumvent many known problems and limitations and to open new possibilities for the modality.