Numerical Analysis of Corrugated Steel Pipes Rehabilitated Using Cementitious Liner**

FY 2018-19

Summary
Corrugated steel pipes (CSPs) are widely used to construct culverts. Abrasion and corrosion are now common causes of CSP deterioration. Owing to its ease of use and low cost, cementitious spray lining is being employed to rehabilitate CSP culverts in terms of both structural strength and hydraulic performance. However, the performance of rehabilitated CSP has not been adequately studied and existing standards lack design guidelines encompassing spray lining. Moreover, these standards fail to properly account for overburden/vehicle loads which can be the source of most of the demand on the rehabilitated pipe system. Researchers have used full scale testing to investigate the performance of circular steel pipes lined with sprayed cementitious liners, and have proposed design methods for selecting the liner thickness sufficient to ensure adequate strength of the sprayed liner within a circular CSP. However, the proposed design methods have not yet been extended to include non-circular sewers. Hence, the main goal of the proposed research would be to conduct modeling/analysis of deteriorated CSP of various geometries with non-circular cross-sections under different loading and field conditions in order to analyze pipe and liner performance and response. The analysis of both deteriorated and rehabilitated pipes can reveal how the sprayed liner will contribute to enhancing the load bearing capacity and service load response of the CSP. Based on the findings, a design procedure for rehabilitation of non-circular pipes using cementitious spray lining will be proposed. The proposed research will establish design guidelines for spray-on liners and the calculations for required liner thickness, and better understanding of how this rehabilitation technique improves pipe strength and life expectancy. These advances represents a substantial competitive advantage for the partner company, so they can offer their clients more cost-effective rehabilitation options. Municipal and provincial infrastructure owners can save from 30% to 60% of rehabilitation costs compared to conventional pipe replacement, saving millions of dollars on an annual basis across Canada.*
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
536487-2018
Name nom
Moore, Ian
Department département
Civil Engineering
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1002
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Geotechnical engineering (including engineering geology)
Research subject fr
Géotechnique (y compris génie géologique)
Partie
1
Nb partie
1
Application title
Numerical Analysis of Corrugated Steel Pipes Rehabilitated Using Cementitious Liner**
Keyword
NSERC
Application summary
Corrugated steel pipes (CSPs) are widely used to construct culverts. Abrasion and corrosion are now common causes of CSP deterioration. Owing to its ease of use and low cost, cementitious spray lining is being employed to rehabilitate CSP culverts in terms of both structural strength and hydraulic performance. However, the performance of rehabilitated CSP has not been adequately studied and existing standards lack design guidelines encompassing spray lining. Moreover, these standards fail to properly account for overburden/vehicle loads which can be the source of most of the demand on the rehabilitated pipe system. Researchers have used full scale testing to investigate the performance of circular steel pipes lined with sprayed cementitious liners, and have proposed design methods for selecting the liner thickness sufficient to ensure adequate strength of the sprayed liner within a circular CSP. However, the proposed design methods have not yet been extended to include non-circular sewers. Hence, the main goal of the proposed research would be to conduct modeling/analysis of deteriorated CSP of various geometries with non-circular cross-sections under different loading and field conditions in order to analyze pipe and liner performance and response. The analysis of both deteriorated and rehabilitated pipes can reveal how the sprayed liner will contribute to enhancing the load bearing capacity and service load response of the CSP. Based on the findings, a design procedure for rehabilitation of non-circular pipes using cementitious spray lining will be proposed. The proposed research will establish design guidelines for spray-on liners and the calculations for required liner thickness, and better understanding of how this rehabilitation technique improves pipe strength and life expectancy. These advances represents a substantial competitive advantage for the partner company, so they can offer their clients more cost-effective rehabilitation options. Municipal and provincial infrastructure owners can save from 30% to 60% of rehabilitation costs compared to conventional pipe replacement, saving millions of dollars on an annual basis across Canada.*