Wearable tonometry and oscillometry for data-driven cuffless blood pressure waveform monitoring

FY 2024-25

Summary
The last decade has seen a tremendous increase in the number of people wearing fitness trackers for health monitoring. Despite adoption by the public, there still exists a chasm between medical grade health monitors and wearable devices. For instance, cuffless blood pressure (BP) monitors allow for continuous measurement of BP, therefore providing a more complete picture of the patient's state. However, the European Society of Hypertension does not recommend the clinical adoption of cuffless devices due to poor accuracy and lack of robust validation in representative situations. Although my recent work on continuously measuring the BP waveform (instead of peak and trough) with physiological measures coupled with a BP model overcome these issues, very important technical challenges need addressing to bring the method to fruition, namely: (1) the current methods for measuring the BP waveform to build subject-specific data-driven models require cumbersome expensive devices; (2) the large range of BP needed for building an accurate BP model requires the user to go through a series of BP challenges, which might limit user compliance; and (3) increased confidence in the black-box BP model with a deeper understanding of the underlying physiology is required for clinicians to fully adopt the method. The solutions to these technological challenges are the key innovations of the proposed research program, wherein the long-term goal is to create cardiovascular digital twins through mechatronics devices, subject-specific models, and algorithms. The following research objectives are established for the next five years. The first objective is to develop a wearable applanation tonometer to measure the BP waveform sporadically during daily life, a transformative device that will track central BP, clinically more meaningful than peripheral BP, and stroke volume to monitor patients like post-partum women and heart failure survivors. This device will also provide a convenient way of measuring the BP waveform for building subject-specific models, removing the need for a third-party device. The second objective is to leverage large databases and define conditions for opportunistic retraining of the BP model by interaction with the wearable tonometer. This objective will take discrete measurements and make it a continuous estimation of the BP waveform to capture sudden change in patients physiology, which is impossible with current methods. The third objective is to developed physical models of arterial viscoelasticity to better understand the wearable measurements and the black-box BP model. Theses models will be used to estimate viscoelastic property changes with time due to vasomotor tone, giving a more actionable representation of patients state. This program will train students with a set of unique skills in engineering and physiology that prepares them to join a range of critical Canadian industries, from health science to applied artificial intelligence.
Program
Discovery Launch Supplement
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
DGECR-2024-00277
Name nom
Landry, Céderick
Department département
Génie
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2024
Award amount
12500
Program id
DGECR
Program name en
Discovery Launch Supplement
Program name fr
Supplément Tremplin vers la découverte
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Wearable tonometry and oscillometry for data-driven cuffless blood pressure waveform monitoring
Keywords
cuffless blood pressure measurement; mechatronics; artificial neural network; cardiovascular physiology; system identification; biomechanical properties; signal processing; waveform analysis; arterial stiffness; viscoelasticity
Application summary
The last decade has seen a tremendous increase in the number of people wearing fitness trackers for health monitoring. Despite adoption by the public, there still exists a chasm between medical grade health monitors and wearable devices. For instance, cuffless blood pressure (BP) monitors allow for continuous measurement of BP, therefore providing a more complete picture of the patient's state. However, the European Society of Hypertension does not recommend the clinical adoption of cuffless devices due to poor accuracy and lack of robust validation in representative situations. Although my recent work on continuously measuring the BP waveform (instead of peak and trough) with physiological measures coupled with a BP model overcome these issues, very important technical challenges need addressing to bring the method to fruition, namely: (1) the current methods for measuring the BP waveform to build subject-specific data-driven models require cumbersome expensive devices; (2) the large range of BP needed for building an accurate BP model requires the user to go through a series of BP challenges, which might limit user compliance; and (3) increased confidence in the black-box BP model with a deeper understanding of the underlying physiology is required for clinicians to fully adopt the method. The solutions to these technological challenges are the key innovations of the proposed research program, wherein the long-term goal is to create cardiovascular digital twins through mechatronics devices, subject-specific models, and algorithms. The following research objectives are established for the next five years. The first objective is to develop a wearable applanation tonometer to measure the BP waveform sporadically during daily life, a transformative device that will track central BP, clinically more meaningful than peripheral BP, and stroke volume to monitor patients like post-partum women and heart failure survivors. This device will also provide a convenient way of measuring the BP waveform for building subject-specific models, removing the need for a third-party device. The second objective is to leverage large databases and define conditions for opportunistic retraining of the BP model by interaction with the wearable tonometer. This objective will take discrete measurements and make it a continuous estimation of the BP waveform to capture sudden change in patients physiology, which is impossible with current methods. The third objective is to developed physical models of arterial viscoelasticity to better understand the wearable measurements and the black-box BP model. Theses models will be used to estimate viscoelastic property changes with time due to vasomotor tone, giving a more actionable representation of patients state. This program will train students with a set of unique skills in engineering and physiology that prepares them to join a range of critical Canadian industries, from health science to applied artificial intelligence.