Grant: Research Tools and Instruments - Category 1 (<$150,000)

University of Saskatchewan

$47,373.00

Telemetry blood pressure and activity monitoring in conscious, unrestraind fish

FY 2006-07

Summary
The equipment requested is a telemetry blood pressure and activity monitoring system for fish. This system would provide state-of-the-art capability to continuously, remotely monitor cardiovascular function (heart rate, blood pressure) and activity (muscle movement) in fish as small as adult goldfish or juvenile rainbow trout while conscious and freely moving in a normal tank. Blood pressure telemetry has revolutionized mammalian blood pressure studies by revealing the overshadowing effect that restraint and anaesthetics can have on cardiovascular physiology studies, particularly where effects of a substance or disease are subtle. Measurements can be made intensively over short period (many readings per second) to monitor responses to an acute stimulus, averaged over a longer period to give very accurate average daily values, to monitor daily fluctuations with activity patterns (night versus day) or to monitor changes in heart rate and blood pressure over a long period (months).  Furthermore, the system can also be used to remotely and continuously monitor movement in a freely moving conscious fish, a highly useful behavioural end-point in toxicological studies. Overall, the addition of this equipment to my NSERC Discovery research program would greatly improve the physiological accuracy of mechanisms determined to govern fish cardiovascular function, contributing to both the short-term and long-term objectives I originally proposed.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Location
Saskatchewan, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
344962-2007
Name nom
Weber, Lynn
Department département
Veterinary Biomedical Sciences
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2006
Competition year année de concours
2007
Award amount
47373
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1011
Committee name en
Integrative Animal Biology
Committee name fr
Biologie Animale Intégrative
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
5506
Research subject group en
Animal biology
Research subject group fr
Biologie animale
Research subject en
Animal circulation
Research subject fr
Circulation animale
Partie
1
Nb partie
1
Application title
Telemetry blood pressure and activity monitoring in conscious, unrestraind fish
Keyword
NA
Application summary
The equipment requested is a telemetry blood pressure and activity monitoring system for fish. This system would provide state-of-the-art capability to continuously, remotely monitor cardiovascular function (heart rate, blood pressure) and activity (muscle movement) in fish as small as adult goldfish or juvenile rainbow trout while conscious and freely moving in a normal tank. Blood pressure telemetry has revolutionized mammalian blood pressure studies by revealing the overshadowing effect that restraint and anaesthetics can have on cardiovascular physiology studies, particularly where effects of a substance or disease are subtle. Measurements can be made intensively over short period (many readings per second) to monitor responses to an acute stimulus, averaged over a longer period to give very accurate average daily values, to monitor daily fluctuations with activity patterns (night versus day) or to monitor changes in heart rate and blood pressure over a long period (months).  Furthermore, the system can also be used to remotely and continuously monitor movement in a freely moving conscious fish, a highly useful behavioural end-point in toxicological studies. Overall, the addition of this equipment to my NSERC Discovery research program would greatly improve the physiological accuracy of mechanisms determined to govern fish cardiovascular function, contributing to both the short-term and long-term objectives I originally proposed.