Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Alliance Grants

University of Manitoba

$22,608.00

Connection of Hollow-Core Slabs to Masonry Walls

FY 2022-23

Summary
Precast, prestressed hollow-core slabs (HCS) are widely used in building construction since they offer an economical solution for a floor or roof system, especially those with large spans. Other advantages of HCS include ease and speed of construction, high levels of fire resistance, enhanced durability, and sustainability. It was estimated that, between 1962 and 2016, more than 50 million square meters of HCS floors have been constructed in Canada. As standard construction practice, reinforcing bars are used to connect the HCS floors to the building structure. The current design manuals illustrate numerous examples of detailing for HCS bearing connections to supporting structures. However, due to lack of experimental data, a design methodology or an expected capacity are not included in the description. In collaboration with the Canadian Precast/Prestressed Concrete Institute, which is the prime source of technical information about precast/prestressed concrete in Canada, and Tower Engineering Group, a Canadian consulting firm with focus on precast buildings, the applicant has conducted an extensive research study to investigate the behaviour of bar connection configurations that are commonly used in Eastern Canada. It was concluded that such bar connections did not satisfy the requirements for masonry buildings of three-or-more storeys under tension forces. This indicates that currently used reinforcing bar connections cannot ensure the structural integrity of HCS floors. Based on the findings of the above study, this research proposal focuses on the connection between HCS and supporting masonry walls using typical Western Canada reinforcing bar details, which is expected to provide higher lateral capacity and a lower lateral displacement compared to Eastern Canada detailing. Full-scale laboratory testing, analytical and numerical investigations will be conducted to assess the performance of such connections. Four highly qualified personnel will be trained through this project. This work will result in reliable design guidelines and will lead to safe and new structures with improved performance and better durability for infrastructure owners such as Municipalities and Public Works.
Program
Alliance Grants
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
570840-2021
Name nom
El-Salakawy, Ehab EF
Department département
Civil Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2021
Award amount
22608
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Installment
inst:2
Partie
1
Nb partie
2
Application title
Connection of Hollow-Core Slabs to Masonry Walls
Application summary
Precast, prestressed hollow-core slabs (HCS) are widely used in building construction since they offer an economical solution for a floor or roof system, especially those with large spans. Other advantages of HCS include ease and speed of construction, high levels of fire resistance, enhanced durability, and sustainability. It was estimated that, between 1962 and 2016, more than 50 million square meters of HCS floors have been constructed in Canada. As standard construction practice, reinforcing bars are used to connect the HCS floors to the building structure. The current design manuals illustrate numerous examples of detailing for HCS bearing connections to supporting structures. However, due to lack of experimental data, a design methodology or an expected capacity are not included in the description. In collaboration with the Canadian Precast/Prestressed Concrete Institute, which is the prime source of technical information about precast/prestressed concrete in Canada, and Tower Engineering Group, a Canadian consulting firm with focus on precast buildings, the applicant has conducted an extensive research study to investigate the behaviour of bar connection configurations that are commonly used in Eastern Canada. It was concluded that such bar connections did not satisfy the requirements for masonry buildings of three-or-more storeys under tension forces. This indicates that currently used reinforcing bar connections cannot ensure the structural integrity of HCS floors. Based on the findings of the above study, this research proposal focuses on the connection between HCS and supporting masonry walls using typical Western Canada reinforcing bar details, which is expected to provide higher lateral capacity and a lower lateral displacement compared to Eastern Canada detailing. Full-scale laboratory testing, analytical and numerical investigations will be conducted to assess the performance of such connections. Four highly qualified personnel will be trained through this project. This work will result in reliable design guidelines and will lead to safe and new structures with improved performance and better durability for infrastructure owners such as Municipalities and Public Works.