Grant: Engage Grants Program
University of Guelph
$25,000.00
Evaluating the efficacy of UVPure disinfection systems to inactivate human adenovirus in water
FY 2016-17
Summary
A critical problem associated with UV disinfection systems, in general, is the lack of testing using the specific human pathogens that are deemed to be UV resistant. The main issue resides in the differences in UV susceptibility between the non-pathogenic surrogates that are typically utilized in UV disinfection testing and the pathogens they are representing. For adenovirus this is particularly problematic as it is considered one of the most UV resistant human pathogens. Adenovirus requires several fold higher UV doses than other microorganisms to achieve a 4log reduction. In addition, even after UV exposure the virus may still release itsDNA into the host cell where the UV-damaged adenovirus genome can be repaired by the host cell. These traits are not observed in the surrogates typically used, such as the bacteriophage MS2. UVPure is a privately owned, Canadian company that develops and manufactures technically advanced UV purification systems. These systems are based upon low-pressure UV using the company's patented Crossfire technology for use in low flow environments. The aim of this UVpure - UofG collaboration is to evaluate the efficacy of the UVpure system in inactivating human adenovirus strains 40 and 41 in waters of varying UV transmittance (UVT).Adenovirus strains 40 and 41 were selected for this project as they are two important waterborne pathogens with high UV resistance and are the most common adenovirus strains causing gastroenteric illness. Virus samples will be tested in a cell infectivity assay to evaluate infectivity prior to and following UV inactivation. In addition, viral DNA and proteins will be collected to evaluate DNA lesions and protein damage caused by the UV treatment. As such, a focus of this project will be to evaluate the efficacy of the UVpure system to disrupt the viral proteins and DNA in water conditions with varying UVT. This is important to test, particularly for high UVT water, such as groundwater, where the flow through the system may be increased and may result in organisms such as adenovirus not receiving a sufficient UV dose for inactivation. The overall benefits of this project are the implementation of effective UV disinfection in Canada to provide long-term water security.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
499289-2016
Name nom
Zytner, Richard
Department département
Engineering, School of
Organization id
24
Institution établissement
University of Guelph
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
901
Area of application group en
Commercial services
Area of application group fr
Services commerciaux
Area of application en
Sanitary engineering
Area of application fr
Génie sanitaire
Research subject code
1501
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Water quality, pollution
Research subject fr
Qualité de l'eau, pollution
Partie
1
Nb partie
1
Application title
Evaluating the efficacy of UVPure disinfection systems to inactivate human adenovirus in water
Keyword
NSERC
Application summary
A critical problem associated with UV disinfection systems, in general, is the lack of testing using the specific human pathogens that are deemed to be UV resistant. The main issue resides in the differences in UV susceptibility between the non-pathogenic surrogates that are typically utilized in UV disinfection testing and the pathogens they are representing. For adenovirus this is particularly problematic as it is considered one of the most UV resistant human pathogens. Adenovirus requires several fold higher UV doses than other microorganisms to achieve a 4log reduction. In addition, even after UV exposure the virus may still release itsDNA into the host cell where the UV-damaged adenovirus genome can be repaired by the host cell. These traits are not observed in the surrogates typically used, such as the bacteriophage MS2. UVPure is a privately owned, Canadian company that develops and manufactures technically advanced UV purification systems. These systems are based upon low-pressure UV using the company's patented Crossfire technology for use in low flow environments. The aim of this UVpure - UofG collaboration is to evaluate the efficacy of the UVpure system in inactivating human adenovirus strains 40 and 41 in waters of varying UV transmittance (UVT).Adenovirus strains 40 and 41 were selected for this project as they are two important waterborne pathogens with high UV resistance and are the most common adenovirus strains causing gastroenteric illness. Virus samples will be tested in a cell infectivity assay to evaluate infectivity prior to and following UV inactivation. In addition, viral DNA and proteins will be collected to evaluate DNA lesions and protein damage caused by the UV treatment. As such, a focus of this project will be to evaluate the efficacy of the UVpure system to disrupt the viral proteins and DNA in water conditions with varying UVT. This is important to test, particularly for high UVT water, such as groundwater, where the flow through the system may be increased and may result in organisms such as adenovirus not receiving a sufficient UV dose for inactivation. The overall benefits of this project are the implementation of effective UV disinfection in Canada to provide long-term water security.