Grant: Engage Grants Program
Ryerson University
$25,000.00
A smart manifold for ground source heat pump applications
FY 2013-14
Summary
Maintaining a comfortable temperature inside a building can require a significant amount of energy. Energy savings can be achieved through the use of geothermal ground source heat pump (GSHP) systems in place of conventional air-conditioners and furnaces. Reductions in energy consumption of 30% to 70% in the heating mode and 20% to 50% in the cooling mode can be obtained using GSHPs. Today, GSHP systems are one of the fastest growing applications of renewable energy in the world, growing at a rate of approximately 30% per year. The tremendous growth of GSHP systems is attributed to their high energy efficiency potential, which can result in both environmental and economic benefits.Ground Source Heat Pumps (GSHPs) pump liquid through underground piping. During the winter months, these systems extract heat from the ground to provide space heating, and similarly they reject heat to the ground in the summer to provide space cooling. Due to the nature of mechanical components, GSHPs operate most efficiently at a single design capacity, usually their maximum capacity. However, during the shoulder seasons (spring and fall) or moderate summer and winter days, only a fraction of the maximum heating and cooling capacity needs to be provided. For current designs, reduced capacity operation during these periods is inefficient. The reasons for this inefficiency is two-fold; first, the pump will slow down to reduce the flowrate through the ground loop and therefore will not be operating at its optimal specifications, and second,with slower flow through the underground piping, the heat transfer with the ground becomes less efficient.The proposed research seeks to design modified GSHP systems that use a valve system or flow manifold and associated control system to alleviate the aforementioned problem by directing fluid flow through only a portion of the ground loop piping based on the current heating or cooling demand. Such a system would allow the pump to operate at full speed and ground heat transfer to be maximized while a portion of the underground piping is bypassed in order to efficiently meet reduced demand.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
453130-2013
Name nom
Dworkin, Seth
Department département
Mechanical and Industrial Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
A smart manifold for ground source heat pump applications
Keyword
NSERC
Application summary
Maintaining a comfortable temperature inside a building can require a significant amount of energy. Energy savings can be achieved through the use of geothermal ground source heat pump (GSHP) systems in place of conventional air-conditioners and furnaces. Reductions in energy consumption of 30% to 70% in the heating mode and 20% to 50% in the cooling mode can be obtained using GSHPs. Today, GSHP systems are one of the fastest growing applications of renewable energy in the world, growing at a rate of approximately 30% per year. The tremendous growth of GSHP systems is attributed to their high energy efficiency potential, which can result in both environmental and economic benefits.Ground Source Heat Pumps (GSHPs) pump liquid through underground piping. During the winter months, these systems extract heat from the ground to provide space heating, and similarly they reject heat to the ground in the summer to provide space cooling. Due to the nature of mechanical components, GSHPs operate most efficiently at a single design capacity, usually their maximum capacity. However, during the shoulder seasons (spring and fall) or moderate summer and winter days, only a fraction of the maximum heating and cooling capacity needs to be provided. For current designs, reduced capacity operation during these periods is inefficient. The reasons for this inefficiency is two-fold; first, the pump will slow down to reduce the flowrate through the ground loop and therefore will not be operating at its optimal specifications, and second,with slower flow through the underground piping, the heat transfer with the ground becomes less efficient.The proposed research seeks to design modified GSHP systems that use a valve system or flow manifold and associated control system to alleviate the aforementioned problem by directing fluid flow through only a portion of the ground loop piping based on the current heating or cooling demand. Such a system would allow the pump to operate at full speed and ground heat transfer to be maximized while a portion of the underground piping is bypassed in order to efficiently meet reduced demand.