Grant: Alliance Grants
University of British Columbia
$50,000.00
Development of low-cost, compact fibre optic O2 and CO2 gas sensors for COVID-19 applications of portable metabolic analyzers_x000d_ _x000d_
FY 2020-21
Summary
The goal of this partnership is to research and develop inexpensive optical technologies adapted from off-the-shelf components to improve the performance and reduce the cost of portable metabolic analyzers. Portable metabolic analyzers are wearable sensors capable of measuring oxygen consumption and carbon dioxide production in the lungs, key indicators of human physiology and human health. There are at least two potential COVID-19 related applications of portable metabolic analyzers. First, they can be used to provide real-time monitoring of COVID-19 patients outside of the hospital setting. Second, they can be used in conjunction with open ventilator circuits to provide biofeedback during ventilation, an important capability to reduce the possibility of hypo- or hyper-ventilation. There are two obstacles associate with portable metabolic analyzers which must be overcome before they can be used in such applications. First, portable metabolic analyzers are too expensive for wide-scale use; the cheapest version on the market is the USD 5000 version sold by VO2 Master. Second, these analyzers require regular recalibration using compressed gas containers, limiting their ease of use.
This project will explore the feasibility of a fibre-optic gas sensor for detecting oxygen and carbon dioxide concentrations under metabolically relevant conditions. The advantages of a fibre-based detector include its small size, absence of electrical interference, remote-sensing capabilities, and low cost. Fibre-optic sensors can be constructed from off-the-shelf components (such as LEDs, photodetectors, and optical fibres) and are thus readily prototyped and could potentially be applied in single-use applications, eliminating the need for costly recalibration required by conventional sensors. Researchers at UBC Okanagan will construct a fibre-based gas sensor prototype, which will be tested, calibrated, and integrated into a portable face-worn mask in collaboration with technical staff from VO2 Master.
Program
Alliance Grants
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
554951-2020
Name nom
Chau, Kenneth
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2020
Award amount
50000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Development of low-cost, compact fibre optic O2 and CO2 gas sensors for COVID-19 applications of portable metabolic analyzers_x000d_
_x000d_
Keyword
NSERC
Application summary
The goal of this partnership is to research and develop inexpensive optical technologies adapted from off-the-shelf components to improve the performance and reduce the cost of portable metabolic analyzers. Portable metabolic analyzers are wearable sensors capable of measuring oxygen consumption and carbon dioxide production in the lungs, key indicators of human physiology and human health. There are at least two potential COVID-19 related applications of portable metabolic analyzers. First, they can be used to provide real-time monitoring of COVID-19 patients outside of the hospital setting. Second, they can be used in conjunction with open ventilator circuits to provide biofeedback during ventilation, an important capability to reduce the possibility of hypo- or hyper-ventilation. There are two obstacles associate with portable metabolic analyzers which must be overcome before they can be used in such applications. First, portable metabolic analyzers are too expensive for wide-scale use; the cheapest version on the market is the USD 5000 version sold by VO2 Master. Second, these analyzers require regular recalibration using compressed gas containers, limiting their ease of use.
This project will explore the feasibility of a fibre-optic gas sensor for detecting oxygen and carbon dioxide concentrations under metabolically relevant conditions. The advantages of a fibre-based detector include its small size, absence of electrical interference, remote-sensing capabilities, and low cost. Fibre-optic sensors can be constructed from off-the-shelf components (such as LEDs, photodetectors, and optical fibres) and are thus readily prototyped and could potentially be applied in single-use applications, eliminating the need for costly recalibration required by conventional sensors. Researchers at UBC Okanagan will construct a fibre-based gas sensor prototype, which will be tested, calibrated, and integrated into a portable face-worn mask in collaboration with technical staff from VO2 Master.