Functional near infrared spectroreflectometry (fNIRS) is a noninvasive, safe, minimally intrusive, and high temporal resolution system for real-time and long-term brain imaging. It allows detecting both fast neuronal and slow hemodynamic signals. Besides of the significant advantages of fNIRS system it still suffers from few drawbacks including low spatial resolution, high-level noise, inflexibility and high sensitivity to movement. In order to overcome the limitations of currently available non-portable fNIRS systems, we have proposed to design and prototype a new miniaturized, reconfigurable and low-noise light detector. It applies adaptive-optimal control implemented in complementary metal-oxidesemiconductor (CMOS) technology to achieve a smart imaging sensor for several applications.
Department
Program
Travel Awards - Institute Community Support
Recipient
Location
Quebec, Canada
Type
Grant
Source
CIHR Funding Decisions Database
As published
Id
278623
Name
Kamrani Ehsan
Region
Québec
Country
Canada
Orgtype
Research Institution
Instname2
Circulatory and Respiratory Health
Theme2
Biomedical
Prcname2
Institute of Circulatory and Respiratory Health
Projecttitle
A Portable Wireless NIRS System Combined with EEG for Bedside Monitoring of Stroke and Cardiac Patients
Programtype2
Undefined
Orgnameinp2
Direct Payment
Cihramount2
$850
Cihrequipment2
$0
Programname2
Travel Awards - Institute Community Support
Keyworddelim
Analog Integrated Circuits And Systems; Bci; Biomedical Circuits And Systems; Biomedical Imaging Systems; Fnirs; Optical Sensors; Optoelectronics & Bioopics; Photodetectors And Image Sensors; Real-Time Brain Monitoring; Stroke Or Epileptic Seizures Detection
Abstract
Functional near infrared spectroreflectometry (fNIRS) is a noninvasive, safe, minimally intrusive, and high temporal resolution system for real-time and long-term brain imaging. It allows detecting both fast neuronal and slow hemodynamic signals. Besides of the significant advantages of fNIRS system it still suffers from few drawbacks including low spatial resolution, high-level noise, inflexibility and high sensitivity to movement. In order to overcome the limitations of currently available non-portable fNIRS systems, we have proposed to design and prototype a new miniaturized, reconfigurable and low-noise light detector. It applies adaptive-optimal control implemented in complementary metal-oxidesemiconductor (CMOS) technology to achieve a smart imaging sensor for several applications.
Competitiondate
201301
Approvedterm2
0 yr 3 mths
Pinamesdelim
Kamrani, Ehsan
Approvedterm
0 an 3 mois
Cihrcontribution2
Inst of Circ &Respiratory Hlth~ $850~ $0~