Grant: Collaborative Research and Development Grants
University of Alberta
$11,400.00
Steel plate shear walls for economical industrial protective structures
FY 2013-14
Summary
In recent years, petrochemical facilities have become increasingly complex. As a result, the need for blast-resistant buildings (e.g., control houses) on these sites has increased considerably due to an elevated risk of accidental explosion. In many cases, such explosions cause substantial financial and equipment losses, along with personnel injury and, potentially, casualties. Depending on the type of process plant and its configuration on the site, blast-resistant structures may be needed to protect personnel, as well as to provide the possibility of a controlled shutdown to minimise the impact of the incident on plant operation. In fact, the potential for accidental explosions exists in many other Canadian industries besides the petrochemical industry, leading to the need for functional structures that also possess a protective capability.A lateral force resisting system that has attracted significant attention in recent decades--particularly for seismic applications--is the steel plate shear wall. Past research on this system, through both experiments and numerical analyses, has demonstrated its excellent performance under both quasi-static and dynamic cyclic loading. In particular, it has been shown in numerous experiments to have a unique ability to absorb very large amounts of energy under inelastic loading, without degrading in capacity. This desirable characteristic of steel plate shear walls is enhanced by their high degree of load-path redundancy. Despite these proven characteristics, the performance of steel plate shear walls under accidental blast loading, and thus their potential applications for protective structures in industrial facilities, has not been investigated systematically. This proposed research project aims to explore the competency of the steel plate shear wall system under accidental blast loading for industrial applications, in order to expand their use beyond the traditional application of earthquake load resistance.
Program
Collaborative Research and Development Grants
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
435424-2012
Name nom
Driver, Robert
Department département
Civil and Environmental Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2012
Award amount
11400
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1100
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural engineering
Research subject fr
Génie des structures
Partie
2
Nb partie
2
Application title
Steel plate shear walls for economical industrial protective structures
Keyword
NSERC
Application summary
In recent years, petrochemical facilities have become increasingly complex. As a result, the need for blast-resistant buildings (e.g., control houses) on these sites has increased considerably due to an elevated risk of accidental explosion. In many cases, such explosions cause substantial financial and equipment losses, along with personnel injury and, potentially, casualties. Depending on the type of process plant and its configuration on the site, blast-resistant structures may be needed to protect personnel, as well as to provide the possibility of a controlled shutdown to minimise the impact of the incident on plant operation. In fact, the potential for accidental explosions exists in many other Canadian industries besides the petrochemical industry, leading to the need for functional structures that also possess a protective capability.A lateral force resisting system that has attracted significant attention in recent decades--particularly for seismic applications--is the steel plate shear wall. Past research on this system, through both experiments and numerical analyses, has demonstrated its excellent performance under both quasi-static and dynamic cyclic loading. In particular, it has been shown in numerous experiments to have a unique ability to absorb very large amounts of energy under inelastic loading, without degrading in capacity. This desirable characteristic of steel plate shear walls is enhanced by their high degree of load-path redundancy. Despite these proven characteristics, the performance of steel plate shear walls under accidental blast loading, and thus their potential applications for protective structures in industrial facilities, has not been investigated systematically. This proposed research project aims to explore the competency of the steel plate shear wall system under accidental blast loading for industrial applications, in order to expand their use beyond the traditional application of earthquake load resistance.