Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

McMaster University

$43,900.00

Flow induced vibrations in heat exchanger tube arrays

FY 2006-07

Summary
When a flexible structure is exposed to a high velocity flowing fluid, the stucture is induced to vibrate.  If these vibrations are excessive, structural failure may occur.  A familiar example is spectaclar collapse of the Tacoma Narrows Bridge.  The proposed research examines the vibrations of power or chemical plant heat exchanger tubes caused by liquid, gas or steam flows. The objective is to understand the fluid forces which cause the vibrations and thereby, to develop methods for designing against damaging vibrations.  The particular applications are related to improving performance and reliability of heat exchangers, condensers and steam generators in power (nulcear and fossil) and chemical process plants.    Heat exchanger tubes are often long and flexible and may be induced to vibrate excessively by fluid flowing across them.  In the case of nuclear steam generators, this can cause a leak of heavy water from the core of the reactor.  The proposed research will help in developing an understanding of the conditions which lead to damaging tube vibration.  The results will assist the development of design codes which ensure the reliability of heat exchangers in service or of analysis codes for predicting the reliability of aging equipment.     One of the projects involves heat exchanger tubes with fins used to enhance heat transfer.  The fins appear to enhance flow instability in tube arrays and little information currently exists for design against such problems.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
8284-2006
Name nom
Weaver, David
Department département
Mechanical Engineering
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2006
Competition year année de concours
2006
Award amount
43900
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
13
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
305
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy storage and conversion
Area of application fr
Stockage et transformation de l'énergie
Research subject code
2104
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Vibrations
Research subject fr
Vibrations
Partie
1
Nb partie
5
Application title
Flow induced vibrations in heat exchanger tube arrays
Keyword
NA
Application summary
When a flexible structure is exposed to a high velocity flowing fluid, the stucture is induced to vibrate.  If these vibrations are excessive, structural failure may occur.  A familiar example is spectaclar collapse of the Tacoma Narrows Bridge.  The proposed research examines the vibrations of power or chemical plant heat exchanger tubes caused by liquid, gas or steam flows. The objective is to understand the fluid forces which cause the vibrations and thereby, to develop methods for designing against damaging vibrations.  The particular applications are related to improving performance and reliability of heat exchangers, condensers and steam generators in power (nulcear and fossil) and chemical process plants.    Heat exchanger tubes are often long and flexible and may be induced to vibrate excessively by fluid flowing across them.  In the case of nuclear steam generators, this can cause a leak of heavy water from the core of the reactor.  The proposed research will help in developing an understanding of the conditions which lead to damaging tube vibration.  The results will assist the development of design codes which ensure the reliability of heat exchangers in service or of analysis codes for predicting the reliability of aging equipment.     One of the projects involves heat exchanger tubes with fins used to enhance heat transfer.  The fins appear to enhance flow instability in tube arrays and little information currently exists for design against such problems.