Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Carleton University

$14,622.00

Improving the dosimetry of particle therapy dosimetry using novel detectors and Monte Carlo simulations

FY 2013-14

Summary
Treatments of cancer patients with particle beams are becoming increasingly available worldwide. The ultimate goal of radiation therapy is to kill tumor cells while sparing damage to the surrounding healthy tissues and critical organs. Proton and carbon ion beams create a unique pattern of dose deposition as a function of depth in tissue that can produce superior dose distributions to the target volume when compared to conventional radiation treatments using photon or electron beams. Thus, the rationale for using proton and carbon ion beams clinically is the possibility of decreasing the total integral dose and sparing damage to the surrounding healthy tissues and critical organs, leading to higher doses to the tumor volume when compared to the conventional radiation treatments. However, particle therapy technology is still very immature. From a physics stand point, many aspects require new developments and improvements including: development of detectors that are capable of measuring LET in clinical settings, design of new beam lines which produce beams with improved dosimetric properties, improvement in the dose calculation algorithms to better predict the dose due to secondary particles created from inelastic nuclear interactions, improvement in the dose calculation algorithms to better predict the dose deposited in the distal edge of the beam, development of optimization methods that account for biological effect, improvements in the measurements of dose distribution and improvements in the accuracy of absolute dosimetry. Thus, the overall goal of this research is to further develop and improve the field of particle therapy dosimetry. The objectives of this project are to develop novel detectors for applications in particle therapy; and to use Monte Carlo simulations to assess the accuracy and limitations in the dosimetry of particle therapy treatments, including proton and carbon ion therapy treatments.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
401923-2011
Name nom
Sawakuchi, Gabriel
Department département
Physics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2011
Award amount
14622
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
3
Nb partie
3
Application title
Improving the dosimetry of particle therapy dosimetry using novel detectors and Monte Carlo simulations
Keyword
NSERC
Application summary
Treatments of cancer patients with particle beams are becoming increasingly available worldwide. The ultimate goal of radiation therapy is to kill tumor cells while sparing damage to the surrounding healthy tissues and critical organs. Proton and carbon ion beams create a unique pattern of dose deposition as a function of depth in tissue that can produce superior dose distributions to the target volume when compared to conventional radiation treatments using photon or electron beams. Thus, the rationale for using proton and carbon ion beams clinically is the possibility of decreasing the total integral dose and sparing damage to the surrounding healthy tissues and critical organs, leading to higher doses to the tumor volume when compared to the conventional radiation treatments. However, particle therapy technology is still very immature. From a physics stand point, many aspects require new developments and improvements including: development of detectors that are capable of measuring LET in clinical settings, design of new beam lines which produce beams with improved dosimetric properties, improvement in the dose calculation algorithms to better predict the dose due to secondary particles created from inelastic nuclear interactions, improvement in the dose calculation algorithms to better predict the dose deposited in the distal edge of the beam, development of optimization methods that account for biological effect, improvements in the measurements of dose distribution and improvements in the accuracy of absolute dosimetry. Thus, the overall goal of this research is to further develop and improve the field of particle therapy dosimetry. The objectives of this project are to develop novel detectors for applications in particle therapy; and to use Monte Carlo simulations to assess the accuracy and limitations in the dosimetry of particle therapy treatments, including proton and carbon ion therapy treatments.