Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Windsor

$25,000.00

Investigation and validation of the effectiveness of the ergonomic arm using an ANATERGOARM AEA-15 for automotive assembly operations

FY 2018-19

Summary
Power tools play an important tool in the manufacturing industry. Power tools are used to secure and fasten*screws and bolts for many different types of components/assembly interface conditions. Torque guns, like any*other tool, apply pressure on humans during the process, and may cause injuries to human muscles and joints*due to the reaction forces and the task repetition. Some researchers are focusing on new fastening strategies.*The ANAT (Articulated Nimble Adaptable Trunk) system, designed and fabricated by Robotics Design Inc., is*proposed to be employed as a specialty lift assist. Specifically, this research concentrates on whether the*ANATERGOARM AEA-15 ergo arm can be employed not only to hold the torque guns, but can also absorb*the reaction forces. Robotics Design Inc. personnel have developed a unique solution, but do not have the know*how or the base knowledge/data to support their system in an automotive environment for the torque run down*operations. The goal of this research project is to perform physical and virtual experiments to determine*feasible configuration strategies, and establish a platform for future studies. The feasible configurations,*durability, and usability must be determined for a variety of torqueing scenarios and torque run down strategies.*In tandem with investigating the feasibility of the ANATERGOARM AEA-15 system for this ergonomic*application, the kinematic simulation tools need to be determined, and preliminary simulations developed, as*well as work cell layout reconfigurations. Additional experiments at Robotics Design Inc. will be conducted to*determine the extendibility and scalability of the proposed solution approaches. The ANATERGOARM*AEA-15 solution has the potential to improve worker safety, but this needs to be quantified.*
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
530195-2018
Name nom
Urbanic, RJill
Department département
Industrial and Manufacturing Systems Eng.
Organization id
37
Institution établissement
University of Windsor
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
1700
Research subject group en
Design and manufacturing
Research subject group fr
Conception et fabrication
Research subject en
Design and manufacturing
Research subject fr
Conception et fabrication
Partie
1
Nb partie
1
Application title
Investigation and validation of the effectiveness of the ergonomic arm using an ANATERGOARM AEA-15 for automotive assembly operations
Keyword
NSERC
Application summary
Power tools play an important tool in the manufacturing industry. Power tools are used to secure and fasten*screws and bolts for many different types of components/assembly interface conditions. Torque guns, like any*other tool, apply pressure on humans during the process, and may cause injuries to human muscles and joints*due to the reaction forces and the task repetition. Some researchers are focusing on new fastening strategies.*The ANAT (Articulated Nimble Adaptable Trunk) system, designed and fabricated by Robotics Design Inc., is*proposed to be employed as a specialty lift assist. Specifically, this research concentrates on whether the*ANATERGOARM AEA-15 ergo arm can be employed not only to hold the torque guns, but can also absorb*the reaction forces. Robotics Design Inc. personnel have developed a unique solution, but do not have the know*how or the base knowledge/data to support their system in an automotive environment for the torque run down*operations. The goal of this research project is to perform physical and virtual experiments to determine*feasible configuration strategies, and establish a platform for future studies. The feasible configurations,*durability, and usability must be determined for a variety of torqueing scenarios and torque run down strategies.*In tandem with investigating the feasibility of the ANATERGOARM AEA-15 system for this ergonomic*application, the kinematic simulation tools need to be determined, and preliminary simulations developed, as*well as work cell layout reconfigurations. Additional experiments at Robotics Design Inc. will be conducted to*determine the extendibility and scalability of the proposed solution approaches. The ANATERGOARM*AEA-15 solution has the potential to improve worker safety, but this needs to be quantified.*