Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Idea to Innovation

University of British Columbia

$124,529.00

SmartDrill - Fast, reliable, radiation-free guidance for distal locking of intramedullary nails

FY 2010-11

Summary
The objective of this project is to develop a 'smart' drilling tool (""SmartDrill"") that can substantially reduce operating room time and virtually eliminate radiation exposure to the surgeon during the distal locking phase of intramedullary (IM) nailing of long bone fractures (see Figure 1), one of the most common procedures performed by orthopaedic surgeons. We have successfully demonstrated in the lab that we can accurately measure the location of the screw holes; by adding a realtime guidance display, we expect to be able to eliminate the radiation exposure of the current procedure and reduce the time needed for distal screw locking from a range of 10-30 minutes to a range of 1-3 minutes. Since operating room time can cost from $20-100/minute, such a reduction is extremely valuable. In this project, we plan to move our prototype system from a lab-based version which is currently capable only of making measurements, but not guiding the surgeon in real time, to a near-manufacturable device with realtime targeting capability and to prove that we can achieve the expected time and radiation reduction benefits in both simulated and live surgical settings. More specifically, we will add realtime targeting and display functions to the tool, refine the mechanical design of the system so that it will be practically usable in the operating room, complete sterility testing of a key internal component of the system, conduct lab-based and cadaver studies of the integrated system, contribute to an external effort to decrease the size and weight of the core sensor technology we plan to use, perform an evaluation of the updated system in the operating room, and file patent applications on anticipated new features.
Program
Idea to Innovation
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
395128-2009
Name nom
Hodgson, Antony
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2009
Award amount
124529
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
SmartDrill - Fast, reliable, radiation-free guidance for distal locking of intramedullary nails
Keyword
NSERC
Application summary
The objective of this project is to develop a 'smart' drilling tool (""SmartDrill"") that can substantially reduce operating room time and virtually eliminate radiation exposure to the surgeon during the distal locking phase of intramedullary (IM) nailing of long bone fractures (see Figure 1), one of the most common procedures performed by orthopaedic surgeons. We have successfully demonstrated in the lab that we can accurately measure the location of the screw holes; by adding a realtime guidance display, we expect to be able to eliminate the radiation exposure of the current procedure and reduce the time needed for distal screw locking from a range of 10-30 minutes to a range of 1-3 minutes. Since operating room time can cost from $20-100/minute, such a reduction is extremely valuable. In this project, we plan to move our prototype system from a lab-based version which is currently capable only of making measurements, but not guiding the surgeon in real time, to a near-manufacturable device with realtime targeting capability and to prove that we can achieve the expected time and radiation reduction benefits in both simulated and live surgical settings. More specifically, we will add realtime targeting and display functions to the tool, refine the mechanical design of the system so that it will be practically usable in the operating room, complete sterility testing of a key internal component of the system, conduct lab-based and cadaver studies of the integrated system, contribute to an external effort to decrease the size and weight of the core sensor technology we plan to use, perform an evaluation of the updated system in the operating room, and file patent applications on anticipated new features.