Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Idea to Innovation

University of Toronto

$125,000.00

I2I Phase I: Reagentless sensor technologies for peripheral biochemical monitoring

FY 2021-22

Summary
Wearable sensor systems present a unique opportunity for the continual monitoring of vital signs and health status of an individual. These systems can be integrated into common items such as clothing, contact lenses, bandages, and watches to detect and quantify analytes from mucosal membranes or biological fluids. One major challenge to fully realize these systems is the development of platforms that allow for reagent-free analysis of complex biomolecules such as proteins, nucleic acids, and metabolites in real time. Electrochemical sensors are a powerful platform for environmental or biological monitoring based on inexpensive instrumentation and straightforward measurements of electrical currents. As small (nA) currents can be reliably measured, low detection thresholds are feasible. Several challenges remain for its implementation in practical devices and generalized for all types of protein analytes. We recently developed an enzyme-free and regent-free electrochemical reporter system that exhibits levels of sensitivity suitable for analysis of biological samples without the need for pre-processing. In this project we will integrate these electrochemical sensors into biocompatible probes for in situ biochemical monitoring. We will test the developed device in an animal model of diabetes demonstrating continual and reagent free monitoring of insulin levels from interstitial fluids. Requisite hardware and software for controlling the wearable monitoring device will be developed and tested in the project. The project deliverables will have a large impact on the Canadian population with potential impact in monitoring the health of providing continual biomarker monitoring in healthcare for chronic conditions.
Program
Idea to Innovation
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
561559-2021
Name nom
Kelley, Shana
Department département
Pharmacy, Leslie Dan Faculty of
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2021
Award amount
125000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:1
Partie
1
Nb partie
1
Application title
I2I Phase I: Reagentless sensor technologies for peripheral biochemical monitoring
Keyword
NSERC
Application summary
Wearable sensor systems present a unique opportunity for the continual monitoring of vital signs and health status of an individual. These systems can be integrated into common items such as clothing, contact lenses, bandages, and watches to detect and quantify analytes from mucosal membranes or biological fluids. One major challenge to fully realize these systems is the development of platforms that allow for reagent-free analysis of complex biomolecules such as proteins, nucleic acids, and metabolites in real time. Electrochemical sensors are a powerful platform for environmental or biological monitoring based on inexpensive instrumentation and straightforward measurements of electrical currents. As small (nA) currents can be reliably measured, low detection thresholds are feasible. Several challenges remain for its implementation in practical devices and generalized for all types of protein analytes. We recently developed an enzyme-free and regent-free electrochemical reporter system that exhibits levels of sensitivity suitable for analysis of biological samples without the need for pre-processing. In this project we will integrate these electrochemical sensors into biocompatible probes for in situ biochemical monitoring. We will test the developed device in an animal model of diabetes demonstrating continual and reagent free monitoring of insulin levels from interstitial fluids. Requisite hardware and software for controlling the wearable monitoring device will be developed and tested in the project. The project deliverables will have a large impact on the Canadian population with potential impact in monitoring the health of providing continual biomarker monitoring in healthcare for chronic conditions.