Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments

University of Toronto

$150,000.00

Critical need for absolute molecular weight determination on size exclusion chromatography system

FY 2022-23

Summary
The size, or molecular weight, of a polymer is one of the most important factors in determining physical properties. Viscosity, degree of crystallinity, stiffness, bioavailability, conductivity, and other properties are all intimately associated with molecular weight. For example, for a given identical repeat unit of ethylene, polypropylene with a low molecular weight may be used as a plastic bag but polypropylene with ultrahigh high molecular weight may be used as anti-stab vests. Size exclusion chromatography (SEC) is a ubiquitous equipment to determine the molecular weight. The molecular weight is estimated by the time it takes for the polymer to elute from the column: the smaller the polymer, the more it interacts with the stationary solid phase of the column, the longer it takes to elute. Notably, typical methods widespread in the polymer research community and also at UofT inaccurately determine the molecular weight. Most researchers use a set of standard polymer samples with known molecular weight to create a calibration curve to correlate the time it takes for a polymer to elute and its known molecular weight. However, the time it takes to elute is intimately related to the identity of the polymer. For the same molecular weight, a polymer that is tightly coiled in a select solvent will elute at a different time that a polymer that is loosely coiled. Thus, the identity of the standard polymer samples used to create the calibration curve must match the identity of the polymer to be characterized. Since there are limited standards, often poly(styrene) or poly(methyl methacrylate) is used as a standard. Thus, the molecular weights determined by SEC calibrated against a standard is only a good estimated if the unknown polymer behaves like the standards. As new polymers are being developed at UofT, we are discovering that this estimation is no longer appropriate, where there are very large discrepancies. The requested SEC system coupled with a multi-angle light scattering technique, the first of its type at UofT and surrounding institutions to our knowledge, will enable the local polymer research community to determine absolute molecular weight. Moreover, the selected solvent system of chloroform is missing from UofT, which is the only solvent which solubilizes the new conjugated polymers developed by some of the UofT researchers. Also, it uses a quick analysis procedure and 85% less solvent per run than any system that is available on the market. The five co-PIs include Tran, Khan, Seferos, Winnik, and Bender, with more than 50 highly qualified personnel as potential users at the onset.
Program
Research Tools and Instruments
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RTI-2023-00316
Name nom
Tran, Helen
Department département
Chemistry (St. George Campus) - Chemistry (St. George Campus)
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2023
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1604
Committee name en
Chemistry (RTI)
Committee name fr
Chimie (OIR)
Area of application code
508
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Polymers, rubber and plastics
Area of application fr
Polymères, caoutchouc et plastiques
Research subject code
3750
Research subject group en
Polymer chemistry
Research subject group fr
Chimie des polymères
Research subject en
Polymer chemistry
Research subject fr
Chimie des polymères
Installment
inst:1
Partie
1
Nb partie
1
Application title
Critical need for absolute molecular weight determination on size exclusion chromatography system
Application summary
The size, or molecular weight, of a polymer is one of the most important factors in determining physical properties. Viscosity, degree of crystallinity, stiffness, bioavailability, conductivity, and other properties are all intimately associated with molecular weight. For example, for a given identical repeat unit of ethylene, polypropylene with a low molecular weight may be used as a plastic bag but polypropylene with ultrahigh high molecular weight may be used as anti-stab vests. Size exclusion chromatography (SEC) is a ubiquitous equipment to determine the molecular weight. The molecular weight is estimated by the time it takes for the polymer to elute from the column: the smaller the polymer, the more it interacts with the stationary solid phase of the column, the longer it takes to elute. Notably, typical methods widespread in the polymer research community and also at UofT inaccurately determine the molecular weight. Most researchers use a set of standard polymer samples with known molecular weight to create a calibration curve to correlate the time it takes for a polymer to elute and its known molecular weight. However, the time it takes to elute is intimately related to the identity of the polymer. For the same molecular weight, a polymer that is tightly coiled in a select solvent will elute at a different time that a polymer that is loosely coiled. Thus, the identity of the standard polymer samples used to create the calibration curve must match the identity of the polymer to be characterized. Since there are limited standards, often poly(styrene) or poly(methyl methacrylate) is used as a standard. Thus, the molecular weights determined by SEC calibrated against a standard is only a good estimated if the unknown polymer behaves like the standards. As new polymers are being developed at UofT, we are discovering that this estimation is no longer appropriate, where there are very large discrepancies. The requested SEC system coupled with a multi-angle light scattering technique, the first of its type at UofT and surrounding institutions to our knowledge, will enable the local polymer research community to determine absolute molecular weight. Moreover, the selected solvent system of chloroform is missing from UofT, which is the only solvent which solubilizes the new conjugated polymers developed by some of the UofT researchers. Also, it uses a quick analysis procedure and 85% less solvent per run than any system that is available on the market. The five co-PIs include Tran, Khan, Seferos, Winnik, and Bender, with more than 50 highly qualified personnel as potential users at the onset.
University of Toronto - $150,000 Grant (2022-23) | Canada Spends