Grant: Engage Grants Program
University of Manitoba
$25,000.00
Design and prototype of MEMS force-torque sensor for use with MR-compatible surgical instruments
FY 2011-12
Summary
The proposed research involves the development of MEMS based force-torque sensors, for use in robotic surgery for in-bore magnetic resonance (MR) imaging. In-bore surgical robotics are being investigated by clinicians due to the benefits of having intra-operative MRI and surgical actions to follow each other closely. Difficulties exist, however, due to particular constraints of surgical procedures and imaging technologies. Examples include line-of sight issues, MR compatibility of tools, and loss of tactile information. Consequently, robotic technologies have not yet adopted sensorized tools. Development and integration of MR compatible force-torque sensors into robotic tools is required.
This project is a partnership with IMRIS, who specializes in intra-operative imaging systems and has robotic technology for micro-surgery. IMRIS is looking to augment the haptic feedback of their micro-surgery robotic technology with integrated MEMS based force-torque sensors. The goal is to provide improved force-feedback to enhance tissue differentiation, which is important to re-create the sensation environment and the surgical cues.
The focus of this project is to develop novel technology to measure flex of the tool shaft and at joints. This information can be relayed back to haptics. Results from this project will be extended to other tools and can be applied to a contact sensor on the tool tip. MR compatible MEMS technologies will be explored, including piezoelectric, piezoresistive, and capacitive-based flexure sensors. Investigations will include deposition and development of thin film sensors, substrate issues, sensor mounting to tools, and surgical compatibility and other clinical requirements.
Program
Engage Grants Program
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
417805-2011
Name nom
Shafai, Cyrus
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
25000
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Partie
1
Nb partie
1
Application title
Design and prototype of MEMS force-torque sensor for use with MR-compatible surgical instruments
Keyword
NSERC
Application summary
The proposed research involves the development of MEMS based force-torque sensors, for use in robotic surgery for in-bore magnetic resonance (MR) imaging. In-bore surgical robotics are being investigated by clinicians due to the benefits of having intra-operative MRI and surgical actions to follow each other closely. Difficulties exist, however, due to particular constraints of surgical procedures and imaging technologies. Examples include line-of sight issues, MR compatibility of tools, and loss of tactile information. Consequently, robotic technologies have not yet adopted sensorized tools. Development and integration of MR compatible force-torque sensors into robotic tools is required.
This project is a partnership with IMRIS, who specializes in intra-operative imaging systems and has robotic technology for micro-surgery. IMRIS is looking to augment the haptic feedback of their micro-surgery robotic technology with integrated MEMS based force-torque sensors. The goal is to provide improved force-feedback to enhance tissue differentiation, which is important to re-create the sensation environment and the surgical cues.
The focus of this project is to develop novel technology to measure flex of the tool shaft and at joints. This information can be relayed back to haptics. Results from this project will be extended to other tools and can be applied to a contact sensor on the tool tip. MR compatible MEMS technologies will be explored, including piezoelectric, piezoresistive, and capacitive-based flexure sensors. Investigations will include deposition and development of thin film sensors, substrate issues, sensor mounting to tools, and surgical compatibility and other clinical requirements.