Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Western Ontario

$30,000.00

Design principles for advanced new low-dose photon-counting x-ray detectors for medical radiography

FY 2016-17

Summary
X-ray imaging methods have been under development for over 100 years since the discovery of x rays by RËntgen in 1895, and the complete dependency of modern medicine on x-ray-based diagnostic radiography continues to motivate research to improve costs, efficacy, safety and the potential for screening and early diagnoses. However, there are known risks associated with exposure to radiation and it has been estimated that 1 in 200 of all cancer deaths can be attributed to diagnostic x-ray imaging. This critical need to produce better images with less radiation is the driving motivation for this proposal. The ability of a detector to produce high-quality images with low patient exposures is described by the detective quantum efficiency (DQE) of the detector. The DQE is a number between 0 and 1, expressed as a function of spatial frequency, giving performance relative to an ideal detector. Low-frequency DQE values describe how clearly large lesions can be visualized for a given exposure. High-frequency values describe visualization of small structures and fine detail. An improvement in DQE can be used either to increase image quality or reduce patient exposure, depending on the clinical preference. A new generation of detectors is currently under development that can measure the energy of x-ray photons for use in advanced imaging procedures including CT. While it is essential these photon-counting systems be designed to ensure low dose to patients, the tools required to develop optimal designs are primitive and inadequate for the task. As a consequence, we believe some detectors currently under have little chance of success, while others are not being developed to exploit the full potential of advanced applications. The full potential of these new detectors can only be achieved by developing the mathematical tools that relate physical design parameters and materials to the resulting image quality. We will build on previous contributions and the successes of Fourier-based linear systems to develop a cascaded-systems description of signal and noise as it pertains to photon-counting energy-discriminating detectors. We will introduce x-ray photon energy as an independent parameter in a multi-dimensional approach that will, for the first time, accommodate spatial correlations in image signals that result from energy-dependent x-ray interactions. It is these correlations that degrade the DQE of imaging systems, and are ultimately responsible for poor image quality requiring the use of higher radiation exposures to patients. Results from this research will provide the first means to develop optimal detectors for these advanced applications, and to assess and verify their potential to produce high-quality images while maintaining low levels of x-ray exposure to patients.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2015-05439
Name nom
Cunningham, Ian
Department département
Schulich School of Medicine & Dentistry - Schulich School of Medicine & Dentistr
Organization id
36
Institution établissement
University of Western Ontario
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2015
Award amount
30000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
1
Nb partie
5
Application title
Design principles for advanced new low-dose photon-counting x-ray detectors for medical radiography
Keyword
NSERC
Application summary
X-ray imaging methods have been under development for over 100 years since the discovery of x rays by RËntgen in 1895, and the complete dependency of modern medicine on x-ray-based diagnostic radiography continues to motivate research to improve costs, efficacy, safety and the potential for screening and early diagnoses. However, there are known risks associated with exposure to radiation and it has been estimated that 1 in 200 of all cancer deaths can be attributed to diagnostic x-ray imaging. This critical need to produce better images with less radiation is the driving motivation for this proposal. The ability of a detector to produce high-quality images with low patient exposures is described by the detective quantum efficiency (DQE) of the detector. The DQE is a number between 0 and 1, expressed as a function of spatial frequency, giving performance relative to an ideal detector. Low-frequency DQE values describe how clearly large lesions can be visualized for a given exposure. High-frequency values describe visualization of small structures and fine detail. An improvement in DQE can be used either to increase image quality or reduce patient exposure, depending on the clinical preference. A new generation of detectors is currently under development that can measure the energy of x-ray photons for use in advanced imaging procedures including CT. While it is essential these photon-counting systems be designed to ensure low dose to patients, the tools required to develop optimal designs are primitive and inadequate for the task. As a consequence, we believe some detectors currently under have little chance of success, while others are not being developed to exploit the full potential of advanced applications. The full potential of these new detectors can only be achieved by developing the mathematical tools that relate physical design parameters and materials to the resulting image quality. We will build on previous contributions and the successes of Fourier-based linear systems to develop a cascaded-systems description of signal and noise as it pertains to photon-counting energy-discriminating detectors. We will introduce x-ray photon energy as an independent parameter in a multi-dimensional approach that will, for the first time, accommodate spatial correlations in image signals that result from energy-dependent x-ray interactions. It is these correlations that degrade the DQE of imaging systems, and are ultimately responsible for poor image quality requiring the use of higher radiation exposures to patients. Results from this research will provide the first means to develop optimal detectors for these advanced applications, and to assess and verify their potential to produce high-quality images while maintaining low levels of x-ray exposure to patients.
University of Western Ontario - $30,000 Grant (2016-1… | Canada Spends