Grant: Collaborative Research and Development Grants
Carleton University
$24,000.00
Improvement of Metal-on-Metal Bearing for Orthopedic Implants
FY 2012-13
Summary
Orthopedic implants are used to replace damaged or troubled joints of human bodies. The materials used for orthopedic implants must provide high wear resistance, strength, impact resistance and low friction whilst both surviving in the environment of human bodies and not significantly altering human physiology. While there are many modern materials with excellent tribological properties, the number of materials which are currently approved for use in vivo is far more limited. Of the existing materials in common use CoCrMo alloys are the most popular in implants, for example, prosthetic hips and knees. Deloro Stellite Group manufactures various parts for orthopedic implants such as femoral knee, tibial knee, spheres, shoulders, uni-condyles, staples, ankle, and parts for total hip arthroplasty. The materials use for these implants are mainly ASTM F-75, a medical version of CoCrMo alloy Stellite 21. Although this alloy possesses many merits including high strength, corrosion and wear resistance, and so on, its metal-on-metal bearing still needs improving.
The proposed research attempts to employ a hard coating such as Stellite 720 and Tribaloy T-401 on the ASTM F-75 substrate to improve its metal-on-metal wear resistance. A modified Stellite 21 (ASTM F-75) with increased Cr and N contents will also be produced for improving its metal-on-metal bearings. In addition, Stellite 21 also has another drawback, which is the difficulty in machining and mirror surface polishing. It is expected that the coated Stellite 21 and the modified Stellite 21 will have improved machinability and polishability. To identify the effectiveness and the improvement of the coated Stellite 21 and the modified Stellite 21, their tribological properties (wear and friction), corrosion resistance and biocompatibility will all be investigated in this research. The effects of fabrication process on the properties of the coated Stellite 21 and the modified Stellite 21 will also be studied.
Program
Collaborative Research and Development Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
406354-2010
Name nom
Liu, Rong
Department département
Mechanical & Aerospace Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2010
Award amount
24000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
2006
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Biomaterials
Research subject fr
Biomatériaux
Partie
2
Nb partie
3
Application title
Improvement of Metal-on-Metal Bearing for Orthopedic Implants
Keyword
NSERC
Application summary
Orthopedic implants are used to replace damaged or troubled joints of human bodies. The materials used for orthopedic implants must provide high wear resistance, strength, impact resistance and low friction whilst both surviving in the environment of human bodies and not significantly altering human physiology. While there are many modern materials with excellent tribological properties, the number of materials which are currently approved for use in vivo is far more limited. Of the existing materials in common use CoCrMo alloys are the most popular in implants, for example, prosthetic hips and knees. Deloro Stellite Group manufactures various parts for orthopedic implants such as femoral knee, tibial knee, spheres, shoulders, uni-condyles, staples, ankle, and parts for total hip arthroplasty. The materials use for these implants are mainly ASTM F-75, a medical version of CoCrMo alloy Stellite 21. Although this alloy possesses many merits including high strength, corrosion and wear resistance, and so on, its metal-on-metal bearing still needs improving.
The proposed research attempts to employ a hard coating such as Stellite 720 and Tribaloy T-401 on the ASTM F-75 substrate to improve its metal-on-metal wear resistance. A modified Stellite 21 (ASTM F-75) with increased Cr and N contents will also be produced for improving its metal-on-metal bearings. In addition, Stellite 21 also has another drawback, which is the difficulty in machining and mirror surface polishing. It is expected that the coated Stellite 21 and the modified Stellite 21 will have improved machinability and polishability. To identify the effectiveness and the improvement of the coated Stellite 21 and the modified Stellite 21, their tribological properties (wear and friction), corrosion resistance and biocompatibility will all be investigated in this research. The effects of fabrication process on the properties of the coated Stellite 21 and the modified Stellite 21 will also be studied.