Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Calgary

$2,110.00

Investigation of the effects of endovascular prostheses on cardiovascular fluid-structure interactions

FY 2010-11

Summary
The use of endovascular stents for management of arterial disease is a rapidly emerging area of importance as it is the preferred choice in the management of occlusive, degenerative and aneurismal disease. A stent is inserted into a vessel to re-establish the vessel diameter, whether that is for re-expansion of an obstruction (stenosis) or to contain the flow through a vessel enlargement (aneurysm - see Figure). Despite these differing clinical requirements, all devices must fundamentally adhere to the overarching mechanical principle of appropriate generation of radial force for good approximation of the vessel wall in order that the desired clinical outcome is achieved. If the stent applies too much or too little force the patency of the stent can be compromised. Many clinical issues arise from the compliance mismatch that occurs between the stented region and the native vessel. Compliance mismatches from stents placed in the aorta can produce over dilation, vessel scarring and increased wave reflections resulting in higher blood pressure. Changes in blood flow velocity patterns and wall shear stress are also attributable to compliance mismatch and influence endothelial response, stent migration or blood leakage. In spite of the importance of these concerns, the forces acting on endovascular stents have not been well identified or defined, with little information available in the literature. The goal of my proposed research is to use experimental and numerical models to better understand the loading of endovascular stents, and how they affect vessel/stent compliance, wave propagation, wave reflection, wall shear stress, pressure and flow.
Program
Discovery Grants Program - Individual
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
261969-2010
Name nom
Johnston, Clifton
Department département
Industrial Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
2110
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2200
Research subject group en
Fluid mechanics
Research subject group fr
Mécanique des fluides
Research subject en
Fluid mechanics
Research subject fr
Mécanique des fluides
Partie
1
Nb partie
5
Application title
Investigation of the effects of endovascular prostheses on cardiovascular fluid-structure interactions
Keyword
NSERC
Application summary
The use of endovascular stents for management of arterial disease is a rapidly emerging area of importance as it is the preferred choice in the management of occlusive, degenerative and aneurismal disease. A stent is inserted into a vessel to re-establish the vessel diameter, whether that is for re-expansion of an obstruction (stenosis) or to contain the flow through a vessel enlargement (aneurysm - see Figure). Despite these differing clinical requirements, all devices must fundamentally adhere to the overarching mechanical principle of appropriate generation of radial force for good approximation of the vessel wall in order that the desired clinical outcome is achieved. If the stent applies too much or too little force the patency of the stent can be compromised. Many clinical issues arise from the compliance mismatch that occurs between the stented region and the native vessel. Compliance mismatches from stents placed in the aorta can produce over dilation, vessel scarring and increased wave reflections resulting in higher blood pressure. Changes in blood flow velocity patterns and wall shear stress are also attributable to compliance mismatch and influence endothelial response, stent migration or blood leakage. In spite of the importance of these concerns, the forces acting on endovascular stents have not been well identified or defined, with little information available in the literature. The goal of my proposed research is to use experimental and numerical models to better understand the loading of endovascular stents, and how they affect vessel/stent compliance, wave propagation, wave reflection, wall shear stress, pressure and flow.