Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of British Columbia

$25,000.00

Fouling of membrane cross-flow energy exchanger cores by aerosols

FY 2013-14

Summary
Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained innormally exhausted building or space air and using it to precondition the incoming outdoor ventilation air inHVAC systems. An ERV system pre-cools and dehumidifies the air when the weather is warm, whilehumidifying and pre-heating the air in cooler seasons [1].Polymer ERV systems use a micro-porous polymer membrane that separates indoor and outdoor air streams.This membrane allows heat and water vapor exchange between the two streams. This system is an effectivemeans of reducing energy cost, heating and cooling loads of building ventilation systems, and allows for thescaling down of equipment. Additionally, ERV helps regulate the indoor environment moisture to acomfortable range 40% to 50% relative humidity, which helps to protect the building from moisture-relateddamage and inhibits pathogen growth in the HVAC system. Owing to their compact geometry and roughsurfaces, ERV systems are prone to fouling by particulate matter in working air streams. This fouling maydegrade the heat and moisture exchange properties of the membrane and result in an energy penalty because ofthe higher power needed for the blower to overcome the added pressure drop in the system.A test section will be designed to study how the surface properties of membrane plates and operatingconditions of ERV systems influence the accumulation of airborne particulate matter in these systems. Inparticular, the influence of the particle concentration, air relative humidity and temperature, and working flowrate will be considered. The research will conclude by proposing, based on the experimental results,phenomenological models of ERV fouling that will aid in the design and specification of ERV system filtrationand cleaning for particular applications.
Program
Engage Grants Program
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
461388-2013
Name nom
Rogak, Steven
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Fouling of membrane cross-flow energy exchanger cores by aerosols
Keyword
NSERC
Application summary
Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained innormally exhausted building or space air and using it to precondition the incoming outdoor ventilation air inHVAC systems. An ERV system pre-cools and dehumidifies the air when the weather is warm, whilehumidifying and pre-heating the air in cooler seasons [1].Polymer ERV systems use a micro-porous polymer membrane that separates indoor and outdoor air streams.This membrane allows heat and water vapor exchange between the two streams. This system is an effectivemeans of reducing energy cost, heating and cooling loads of building ventilation systems, and allows for thescaling down of equipment. Additionally, ERV helps regulate the indoor environment moisture to acomfortable range 40% to 50% relative humidity, which helps to protect the building from moisture-relateddamage and inhibits pathogen growth in the HVAC system. Owing to their compact geometry and roughsurfaces, ERV systems are prone to fouling by particulate matter in working air streams. This fouling maydegrade the heat and moisture exchange properties of the membrane and result in an energy penalty because ofthe higher power needed for the blower to overcome the added pressure drop in the system.A test section will be designed to study how the surface properties of membrane plates and operatingconditions of ERV systems influence the accumulation of airborne particulate matter in these systems. Inparticular, the influence of the particle concentration, air relative humidity and temperature, and working flowrate will be considered. The research will conclude by proposing, based on the experimental results,phenomenological models of ERV fouling that will aid in the design and specification of ERV system filtrationand cleaning for particular applications.