Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Waterloo

$25,000.00

Development of a co-culture microfluidic device that mimics vascularized tissues

FY 2018-19

Summary
CellScale develops, manufactures, and commercializes biomaterial mechanical test systems and bioreactors for tissue engineering applications. One of CellScale's current projects is to develop a microfluidic device that mimics the key characteristics of vascularized tissues. Accurately predicting in vivo drug response has been a challenge due to the lack of effective pre-clinical tools, resulting in a 90% false positive rate for compounds in clinical trials. There is a significant demand for new tools to accurately model cell barriers, such as blood vessel endothelium, that regulate the transport of drugs to target tissues. Co-culture systems that can support both endothelial and target tissue cells, represent a critical step towards improving the physiological relevance of in vitro cell culture. The inclusion of endothelial cells has been shown to more accurately replicate in vivo drug response, extend cell viability, and illuminate the nature of disease pathophysiology. Therefore, here we propose to develop a microfluidic device that can be used as an in vitro model of cell barrier function.*The intended device will have two parallel microfluidic channels separated by a porous membrane. Choosing optimal materials, which possess specific surface properties such as being biocompatible, sterilisable and hydrophilic, is the first task. In particular, the channels should be non-adhesive to cells while the membrane should be adhesive to cells. How to effectively bond/assemble the microfluidic channels, the membrane and other components of the device is the second issue to be addressed. The device material and manufacturing process may affect the flow characteristics in the channels. The flow characteristics are important because the shear stresses introduced by the flow have an impact of the cultured cells. Therefore, a third major task of this project will be to evaluate the impact on flow characteristics of various materials and assembly options. The integration of the expertise and facility available in the applicant's laboratory at the University of Waterloo and CellScale will ensure the success of the proposed co-culture microfluidic device.*
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
533713-2018
Name nom
Ren, Carolyn
Department département
Mechanical Engineering and Mechatronics
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
Development of a co-culture microfluidic device that mimics vascularized tissues
Keyword
NSERC
Application summary
CellScale develops, manufactures, and commercializes biomaterial mechanical test systems and bioreactors for tissue engineering applications. One of CellScale's current projects is to develop a microfluidic device that mimics the key characteristics of vascularized tissues. Accurately predicting in vivo drug response has been a challenge due to the lack of effective pre-clinical tools, resulting in a 90% false positive rate for compounds in clinical trials. There is a significant demand for new tools to accurately model cell barriers, such as blood vessel endothelium, that regulate the transport of drugs to target tissues. Co-culture systems that can support both endothelial and target tissue cells, represent a critical step towards improving the physiological relevance of in vitro cell culture. The inclusion of endothelial cells has been shown to more accurately replicate in vivo drug response, extend cell viability, and illuminate the nature of disease pathophysiology. Therefore, here we propose to develop a microfluidic device that can be used as an in vitro model of cell barrier function.*The intended device will have two parallel microfluidic channels separated by a porous membrane. Choosing optimal materials, which possess specific surface properties such as being biocompatible, sterilisable and hydrophilic, is the first task. In particular, the channels should be non-adhesive to cells while the membrane should be adhesive to cells. How to effectively bond/assemble the microfluidic channels, the membrane and other components of the device is the second issue to be addressed. The device material and manufacturing process may affect the flow characteristics in the channels. The flow characteristics are important because the shear stresses introduced by the flow have an impact of the cultured cells. Therefore, a third major task of this project will be to evaluate the impact on flow characteristics of various materials and assembly options. The integration of the expertise and facility available in the applicant's laboratory at the University of Waterloo and CellScale will ensure the success of the proposed co-culture microfluidic device.*