Grant: Engage Grants Program

University of Waterloo

$25,000.00

Development of a methodology for in-vitro evaluation of knee braces

FY 2011-12

Summary
Commercially available knee braces effectively assist individuals who have sustained anterior cruciate ligament (ACL) injury. Karl Hager Limb and brace Ltd. (Edmonton, AB) has come up with a new knee brace that could prevent ACL injury or reduce the severity of the injury under dynamic knee loading. However, there is no existing methodology to test the knee brace for its effectiveness in preventing ACL injury. The objective of the current research is to develop an in-vitro testing methodology to assess the influence of this knee braces on ACL strain during dynamic activities. In the proposed research, motion capture will be performed on a live subject landing from a jump. The motion capture data will be input into a biomechanical model to calculate flexor and extensor moments at the knee. The live subject will then be applying same moments on his knee using a leg press and leg curl exercise machines. A hand held digital durometer will be used to measure the average modulus of elasticity of the stiffened leg muscles during the exercise. A cast of the subject's thigh and leg will be prepared from Sunmate liquid foam that matches the modulus of elasticity of the subject's muscles. The cast will then be mounted on a cadaver knee. A dynamic knee simulator system then applies physiological forces and knee kinematics on the cadaver knee. The knee brace will be mounted on the thigh/leg-shaped foam and the simulation will be repeated. The ACL strain with and without knee braces will be measured multiple times and tested for repeatability. The results will show if the proposed methodology can evaluate the effectiveness of knee braces. Developing a methodology for testing the effectiveness of knee braces is very important as it allows for optimization of the design for better protection. The proposed research will provide a methodology to evaluate the l effectiveness of knee brace in reducing ACL strains. This information will be communicated to our industrial partner who would plan the future research on optimizing the knee braces for better protection.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
418978-2011
Name nom
Chandrashekar, Naveen
Department département
Mechanical Engineering and Mechatronics
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
25000
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
Development of a methodology for in-vitro evaluation of knee braces
Keyword
NSERC
Application summary
Commercially available knee braces effectively assist individuals who have sustained anterior cruciate ligament (ACL) injury. Karl Hager Limb and brace Ltd. (Edmonton, AB) has come up with a new knee brace that could prevent ACL injury or reduce the severity of the injury under dynamic knee loading. However, there is no existing methodology to test the knee brace for its effectiveness in preventing ACL injury. The objective of the current research is to develop an in-vitro testing methodology to assess the influence of this knee braces on ACL strain during dynamic activities. In the proposed research, motion capture will be performed on a live subject landing from a jump. The motion capture data will be input into a biomechanical model to calculate flexor and extensor moments at the knee. The live subject will then be applying same moments on his knee using a leg press and leg curl exercise machines. A hand held digital durometer will be used to measure the average modulus of elasticity of the stiffened leg muscles during the exercise. A cast of the subject's thigh and leg will be prepared from Sunmate liquid foam that matches the modulus of elasticity of the subject's muscles. The cast will then be mounted on a cadaver knee. A dynamic knee simulator system then applies physiological forces and knee kinematics on the cadaver knee. The knee brace will be mounted on the thigh/leg-shaped foam and the simulation will be repeated. The ACL strain with and without knee braces will be measured multiple times and tested for repeatability. The results will show if the proposed methodology can evaluate the effectiveness of knee braces. Developing a methodology for testing the effectiveness of knee braces is very important as it allows for optimization of the design for better protection. The proposed research will provide a methodology to evaluate the l effectiveness of knee brace in reducing ACL strains. This information will be communicated to our industrial partner who would plan the future research on optimizing the knee braces for better protection.