Grant: Alliance Grants
University of Alberta
$100,000.00
Next-generation high performance MEMS ultrasonics
FY 2021-22
Summary
It has long been hypothesized that capacitive micromachined ultrasound transducers (CMUTs) could potentially outperform piezoelectric technologies. However, challenges with dielectric charging, operational hysteresis, and transmit sensitivity have stood as obstacles to these performance outcomes. Typically, a CMUT element is designed with an ensemble of smaller membranes oscillating together to transmit or detect ultrasound waves. However, this approach can lead to unreliable behavior and suboptimal transmit performance if these smaller membranes oscillate out of phase, or collapse at different voltages. After nearly 15 years of work, we recently designed reliable CMUT elements composed of a single long rectangular membrane, that can outperform piezoelectrics. We explored various architectural modifications to the CMUT cavity in order to improve robustness to charging and minimize hysteresis without compromising performance. In order to fabricate CMUTs with these architectural modifications, we developed a double-SOI wafer bonded process with near-100% bonding yield, without the need for aligned bonding. The fabricated single-membrane CMUTs achieved electromechanical efficiency values as high as 0.95, higher than values reported with either piezoelectric transducers or CMUT elements. Moreover, these single-membrane CMUTs exhibited transmit efficiency 2-5 times greater than published CMUT or piezoelectric transducer elements in the 1.5-2.0 MHz range. Our devices demonstrated considerable charging robustness, demonstrating minimal charging over millions of collapse-snapback actuation cycles, while also mitigating hysteresis. In this proposal, we aim to further improve these devices for next-generation high-performance MEMS ultrasonics. Improvements will include high-K dielectrics enabling higher combined transmit and biasing voltages. We also propose an inverted CMUT architecture for piston-like motion, development of high-density through-silicon via technology, and development of prototype linear and 2D arrays. We aim to demonstrate the advantages of our technology using head-on comparisons against state-of-the art commercial probes.
Program
Alliance Grants
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
567531-2021
Name nom
Zemp, Roger
Department département
Engineering, Faculty of
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2021
Award amount
100000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2524
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Ultrasonic/ferroelectric devices and applications
Research subject fr
Applications et dispositifs ultrasoniques et ferroélectriques
Installment
inst:1
Partie
1
Nb partie
3
Application title
Next-generation high performance MEMS ultrasonics
Keyword
NSERC
Application summary
It has long been hypothesized that capacitive micromachined ultrasound transducers (CMUTs) could potentially outperform piezoelectric technologies. However, challenges with dielectric charging, operational hysteresis, and transmit sensitivity have stood as obstacles to these performance outcomes. Typically, a CMUT element is designed with an ensemble of smaller membranes oscillating together to transmit or detect ultrasound waves. However, this approach can lead to unreliable behavior and suboptimal transmit performance if these smaller membranes oscillate out of phase, or collapse at different voltages. After nearly 15 years of work, we recently designed reliable CMUT elements composed of a single long rectangular membrane, that can outperform piezoelectrics. We explored various architectural modifications to the CMUT cavity in order to improve robustness to charging and minimize hysteresis without compromising performance. In order to fabricate CMUTs with these architectural modifications, we developed a double-SOI wafer bonded process with near-100% bonding yield, without the need for aligned bonding. The fabricated single-membrane CMUTs achieved electromechanical efficiency values as high as 0.95, higher than values reported with either piezoelectric transducers or CMUT elements. Moreover, these single-membrane CMUTs exhibited transmit efficiency 2-5 times greater than published CMUT or piezoelectric transducer elements in the 1.5-2.0 MHz range. Our devices demonstrated considerable charging robustness, demonstrating minimal charging over millions of collapse-snapback actuation cycles, while also mitigating hysteresis. In this proposal, we aim to further improve these devices for next-generation high-performance MEMS ultrasonics. Improvements will include high-K dielectrics enabling higher combined transmit and biasing voltages. We also propose an inverted CMUT architecture for piston-like motion, development of high-density through-silicon via technology, and development of prototype linear and 2D arrays. We aim to demonstrate the advantages of our technology using head-on comparisons against state-of-the art commercial probes.