Crack control and leakage criteria for concrete liquid containing structures

FY 2007-08

Summary
Concrete liquid containing structures (CLCS) are used as part of environmental engineering facilities such as water reservoirs and sewage treatment containments. While cylindrical shapes may be structurally suitable for tank construction, rectangular tanks are also often used for water treatment process related purposes.Currently, Canadian design standards do not directly address the structural design of these types of structures and this has led to inconsistency in design of such facilities. Also, many issues related to design of these structures have remained unresolved. There is a growing recognition of the importance of lifeline facilities and in particular CLCS and the need for substantial improvements in the design of such facilities. Careful design and detailing of these structures is necessary to meet the serviceability criteria for crack and leakage control.In recent years, the applicant has carried out extensive analytical investigations (static and dynamic time-history analysis) on the behavior of CLCS. The results have indicated that the current design approach do not represent the true behavior of these types of structures. Also, there is a great deal of inconsistency among the design standards for this important broad class of structures.  This is mainly due to the lack of understanding of the behavior of these structures under static and seismic loading.The main objective of the proposed research study is to develop a rational design procedure, through analytical and experimental programs, for reinforced concrete tanks that assures a safe leak resistant structure. The concepts of water-tightness in liquid containing structures will be investigated. Several full-scale specimens representing segments from typical tank walls will be subjected to static as well as reversed cyclic loading simulating the seismic effects. These specimens while under such loads will be simultaneously subjected to liquid pressure and leakage tests. The analytical study will be based on non-linear finite element method. Both rectangular and circular tanks of various dimensions will be considered in this investigation. It is intended to provide the necessary input for code decision making.
Program
Collaborative Research and Development Grants
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
342347-2006
Name nom
Kianoush, Reza
Department département
Civil Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
30000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Partie
1
Nb partie
3
Application title
Crack control and leakage criteria for concrete liquid containing structures
Keyword
NA
Application summary
Concrete liquid containing structures (CLCS) are used as part of environmental engineering facilities such as water reservoirs and sewage treatment containments. While cylindrical shapes may be structurally suitable for tank construction, rectangular tanks are also often used for water treatment process related purposes.Currently, Canadian design standards do not directly address the structural design of these types of structures and this has led to inconsistency in design of such facilities. Also, many issues related to design of these structures have remained unresolved. There is a growing recognition of the importance of lifeline facilities and in particular CLCS and the need for substantial improvements in the design of such facilities. Careful design and detailing of these structures is necessary to meet the serviceability criteria for crack and leakage control.In recent years, the applicant has carried out extensive analytical investigations (static and dynamic time-history analysis) on the behavior of CLCS. The results have indicated that the current design approach do not represent the true behavior of these types of structures. Also, there is a great deal of inconsistency among the design standards for this important broad class of structures.  This is mainly due to the lack of understanding of the behavior of these structures under static and seismic loading.The main objective of the proposed research study is to develop a rational design procedure, through analytical and experimental programs, for reinforced concrete tanks that assures a safe leak resistant structure. The concepts of water-tightness in liquid containing structures will be investigated. Several full-scale specimens representing segments from typical tank walls will be subjected to static as well as reversed cyclic loading simulating the seismic effects. These specimens while under such loads will be simultaneously subjected to liquid pressure and leakage tests. The analytical study will be based on non-linear finite element method. Both rectangular and circular tanks of various dimensions will be considered in this investigation. It is intended to provide the necessary input for code decision making.