Grant: Engage Grants Program
University of Victoria
$25,000.00
Improved polymer absorption sensors for oil detection
FY 2017-18
Summary
Syscor co. has embarked on an ambitious R&D programme to develop sensor systems to monitor early stageleaks of pipelines for the transport of (crude) oil and natural gas. Early detection allows for timely intervention,so that remediation is easy and cheap. Syscor's technology is based on the Polymer Absorption Sensor (PAS)and they have shown proof-of-principle and have a patent on the technology. The PAS is a sensor where, uponsorption of specific chemicals, there is a physical change in sensor, i.e. the polymer swells because of uptake ofa volatile hydrocarbon, resulting in corresponding change in sensor resistivity. A PAS is generally comprised ofa base elastomeric polymer film, which selectively adsorb target hydrocarbons, and a distribution of conductiveparticles (e.g. one or more metallic or carbon-based particles) to enhance the response changes in the resistanceof the polymer film. However, for commercial viability there remain some outstanding issues, such assensitivity, reversibility, cross-sensitivity and fabrication reproducibility. The sensitivity has to be increased,especially for the least volatile compounds, so that leaks can be detected at the earliest possible time. Thereversibility of the sensors has to be improved because baseline drift makes the data processing unnecessarilycomplicated and over time potentially unreliable, but more importantly diminishes the earliest possibledetection. Cross-sensitivity of a sensor refers to PAS response to a confounding environmental condition (e.g.time-varying fluctuations in temperature and /or water saturation), which interferes with reliable measurements.The cross-sensitivity of PASs has to be mitigated for acquiring readily interpretable data. Reproducibility of thefabrication process is an obvious requirement for a commercial application, but not part of the goals of thisproposal.
Program
Engage Grants Program
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
520079-2017
Name nom
vanVeggel, Frank
Department département
Chemistry
Organization id
7
Institution établissement
University of Victoria
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
602
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Materials performance
Area of application fr
Performance des matériaux
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Partie
1
Nb partie
1
Application title
Improved polymer absorption sensors for oil detection
Keyword
NSERC
Application summary
Syscor co. has embarked on an ambitious R&D programme to develop sensor systems to monitor early stageleaks of pipelines for the transport of (crude) oil and natural gas. Early detection allows for timely intervention,so that remediation is easy and cheap. Syscor's technology is based on the Polymer Absorption Sensor (PAS)and they have shown proof-of-principle and have a patent on the technology. The PAS is a sensor where, uponsorption of specific chemicals, there is a physical change in sensor, i.e. the polymer swells because of uptake ofa volatile hydrocarbon, resulting in corresponding change in sensor resistivity. A PAS is generally comprised ofa base elastomeric polymer film, which selectively adsorb target hydrocarbons, and a distribution of conductiveparticles (e.g. one or more metallic or carbon-based particles) to enhance the response changes in the resistanceof the polymer film. However, for commercial viability there remain some outstanding issues, such assensitivity, reversibility, cross-sensitivity and fabrication reproducibility. The sensitivity has to be increased,especially for the least volatile compounds, so that leaks can be detected at the earliest possible time. Thereversibility of the sensors has to be improved because baseline drift makes the data processing unnecessarilycomplicated and over time potentially unreliable, but more importantly diminishes the earliest possibledetection. Cross-sensitivity of a sensor refers to PAS response to a confounding environmental condition (e.g.time-varying fluctuations in temperature and /or water saturation), which interferes with reliable measurements.The cross-sensitivity of PASs has to be mitigated for acquiring readily interpretable data. Reproducibility of thefabrication process is an obvious requirement for a commercial application, but not part of the goals of thisproposal.