Method and device to detect broken or poorly-connected neutrals in utility distribution systems

FY 2011-12

Summary
Stray voltages are major concerns to utility companies as they affect public safety directly. One of the major causes of stray voltages is the broken or poorly-connected neutral conductors in a distribution system. As a result, determining if there is a broken neutral and finding its location are essential steps to troubleshoot stray voltage problems. Unfortunately, there is no viable method available to help utility engineers and technicians to find broken neutrals. The current practice for neutral condition detection and broken point location is a trial-and-error process, which combines visual inspection and selective disconnection of certain customer sites. Such a process is very time consuming and labor intensive. It often affects customers negatively. In this Collaborative Research and Development (CRD) program, we propose to research and develop a novel portable device for on-line detecting the neutral conditions in a live power distribution system and locating the faulty point when a broken neutral occurs. The proposed device is expected to deliver a promising solution to the challenging problem of neutral condition detection and monitoring. A prototype device will be built and field tested at the Manitoba Hydro distribution systems.The developed technology will improve the productivity of Canadian utility companies and reduce the impact of poor power quality on public.
Program
Collaborative Research and Development Grants
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
385441-2009
Name nom
Li, Yunwei
Department département
Electrical and Computer Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2009
Award amount
46000
Program id
CRDPJ
Program nane en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
2 & 3
Nb partie
3
Application title
Method and device to detect broken or poorly-connected neutrals in utility distribution systems
Keyword
NSERC
Application summary
Stray voltages are major concerns to utility companies as they affect public safety directly. One of the major causes of stray voltages is the broken or poorly-connected neutral conductors in a distribution system. As a result, determining if there is a broken neutral and finding its location are essential steps to troubleshoot stray voltage problems. Unfortunately, there is no viable method available to help utility engineers and technicians to find broken neutrals. The current practice for neutral condition detection and broken point location is a trial-and-error process, which combines visual inspection and selective disconnection of certain customer sites. Such a process is very time consuming and labor intensive. It often affects customers negatively. In this Collaborative Research and Development (CRD) program, we propose to research and develop a novel portable device for on-line detecting the neutral conditions in a live power distribution system and locating the faulty point when a broken neutral occurs. The proposed device is expected to deliver a promising solution to the challenging problem of neutral condition detection and monitoring. A prototype device will be built and field tested at the Manitoba Hydro distribution systems.The developed technology will improve the productivity of Canadian utility companies and reduce the impact of poor power quality on public.