Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Ottawa

$20,000.00

Developing structural models for estimating the wind uplift resistance of commercial roofs

FY 2013-14

Summary
The roof is the most accessible part of a building for purposes of repair and renewal, while its damage ordestruction can have serious effects; hence its strength and durability are a matter of high concern within thecivil engineering industry, but also for the national and international standards associations and for the propertyinsurance companies. The permeability of the roof is ensured through the application of polymer membraneswhich are attached to the structural steel deck of the flat roofs. The extreme wind storms can induce a very highuplift force, causing the membranes to ""balloon"" which in turn will uplift the fasteners which ensure theattachment to the steel deck. Sometimes the fasteners can yield, however, if the steel material of the roof deckis not sufficiently strong, this will bend and will fail under the effect of high intensity winds, hence these haveto respect very strict regulations and guidelines.Canadian General Tower Ltd. (CGT) is one of the North America's leaders in manufacturing of vinyl films andcoated fabrics and they introduced several new roofing products. Until recently CGT was one of the majorproviders of roofing systems on the Canadian and U.S. markets. However, currently more than half of theCompany's roofing products' certifications were discontinued from the US market because these do not complywith the conditions of the U.S. Approval Standards FM4470, due to a discrepancy between the calculationmethod concepts used in the design guidelines and the real structural behaviour of the flat roof systems.University of Ottawa was contacted when looking for an expert in structural engineering for developing newstructural models for simulating the membrane/roofing systems under wind uplift loading. The attachment ofthe roofing membrane along fasteners lines with large spacing produce local loads on the steel deck that canexceed the capacity of the deck; when the same loads are applied punctual uniform loads, onto the surface ofthe deck, these would not produce an overstress and this concept was overseen in FM4470. Such model willre-define the allowable stress calculation and will be appended to the flat roof design guidelines.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
451343-2013
Name nom
Dragomirescu, Elena
Department département
Civil Engineering
Organization id
28
Institution établissement
University of Ottawa
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
20000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
600
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Construction, urban and rural planning
Area of application fr
Construction, urbanisme et aménagement rural
Research subject code
1100
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural engineering
Research subject fr
Génie des structures
Partie
1
Nb partie
1
Application title
Developing structural models for estimating the wind uplift resistance of commercial roofs
Keyword
NSERC
Application summary
The roof is the most accessible part of a building for purposes of repair and renewal, while its damage ordestruction can have serious effects; hence its strength and durability are a matter of high concern within thecivil engineering industry, but also for the national and international standards associations and for the propertyinsurance companies. The permeability of the roof is ensured through the application of polymer membraneswhich are attached to the structural steel deck of the flat roofs. The extreme wind storms can induce a very highuplift force, causing the membranes to ""balloon"" which in turn will uplift the fasteners which ensure theattachment to the steel deck. Sometimes the fasteners can yield, however, if the steel material of the roof deckis not sufficiently strong, this will bend and will fail under the effect of high intensity winds, hence these haveto respect very strict regulations and guidelines.Canadian General Tower Ltd. (CGT) is one of the North America's leaders in manufacturing of vinyl films andcoated fabrics and they introduced several new roofing products. Until recently CGT was one of the majorproviders of roofing systems on the Canadian and U.S. markets. However, currently more than half of theCompany's roofing products' certifications were discontinued from the US market because these do not complywith the conditions of the U.S. Approval Standards FM4470, due to a discrepancy between the calculationmethod concepts used in the design guidelines and the real structural behaviour of the flat roof systems.University of Ottawa was contacted when looking for an expert in structural engineering for developing newstructural models for simulating the membrane/roofing systems under wind uplift loading. The attachment ofthe roofing membrane along fasteners lines with large spacing produce local loads on the steel deck that canexceed the capacity of the deck; when the same loads are applied punctual uniform loads, onto the surface ofthe deck, these would not produce an overstress and this concept was overseen in FM4470. Such model willre-define the allowable stress calculation and will be appended to the flat roof design guidelines.