Grant: Research Tools and Instruments - Category 1 (<$150,000)
University of British Columbia
$56,672.00
Low-pressure, fibre Bragg grating pressure sensors for measurement of cerebrospinal fluid pressures associated with spinal cord injury
FY 2007-08
Summary
Spinal cord injury (SCI) is severe and debilitating with significant personal, social and economic costs. The complex mechanical interactions between the spinal cord and the surrounding cerebrospinal fluid (CSF) and dura both during and after SCI are not well understood. The equipment requested in this proposal will be used to construct a sensitive, low pressure range, Fibre Bragg Grating (FBG) pressure sensor array which is optimized for the high-rate measurement of in vivo CSF pressure prior to, during, and after an SCI in an animal model.In a collaboration between the University of Victoria and University of British Columbia, we have recently developed and implemented a sensor based on fibre-optic strain measurement, for the measurement of intervertebral disc pressures in the range of 0 to 3 MPa. The small size (400 µm diameter), mechanical compliance, immunity to electromagnetic interference, and biocompatibility, make this device ideal for biomedical applications. The current research will utilize a multi-sensor array with an improved light source and detection scheme which will extend its capabilities to the sub-kPa pressure range required for spinal fluid pressure measurement and improve the speed with which it can be measured.By studying the CSF pressure variation above and below the injury site in the hours following SCI, and during surgical decompression of the spinal cord we will provide important information to clinicians studying the feasibility of CSF drainage for spinal cord perfusion management. Also, By measuring the CSF pressure associated with spinal cord injury, we will provide important information to the basic science community, to inform and define the limitations of current animal, synthetic and computational models of SCI which do not currently consider the CSF interaction with the spinal cord and dura during acute SCI.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
360283-2008
Name nom
Cripton, Peter
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2008
Award amount
56672
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1053
Committee name en
Mechanical Engineering - A
Committee name fr
Génie mécanique - A
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Partie
1
Nb partie
1
Application title
Low-pressure, fibre Bragg grating pressure sensors for measurement of cerebrospinal fluid pressures associated with spinal cord injury
Keyword
NA
Application summary
Spinal cord injury (SCI) is severe and debilitating with significant personal, social and economic costs. The complex mechanical interactions between the spinal cord and the surrounding cerebrospinal fluid (CSF) and dura both during and after SCI are not well understood. The equipment requested in this proposal will be used to construct a sensitive, low pressure range, Fibre Bragg Grating (FBG) pressure sensor array which is optimized for the high-rate measurement of in vivo CSF pressure prior to, during, and after an SCI in an animal model.In a collaboration between the University of Victoria and University of British Columbia, we have recently developed and implemented a sensor based on fibre-optic strain measurement, for the measurement of intervertebral disc pressures in the range of 0 to 3 MPa. The small size (400 µm diameter), mechanical compliance, immunity to electromagnetic interference, and biocompatibility, make this device ideal for biomedical applications. The current research will utilize a multi-sensor array with an improved light source and detection scheme which will extend its capabilities to the sub-kPa pressure range required for spinal fluid pressure measurement and improve the speed with which it can be measured.By studying the CSF pressure variation above and below the injury site in the hours following SCI, and during surgical decompression of the spinal cord we will provide important information to clinicians studying the feasibility of CSF drainage for spinal cord perfusion management. Also, By measuring the CSF pressure associated with spinal cord injury, we will provide important information to the basic science community, to inform and define the limitations of current animal, synthetic and computational models of SCI which do not currently consider the CSF interaction with the spinal cord and dura during acute SCI.