Grant: Discovery Grants Program - Individual
University of Manitoba
$24,000.00
Modeling the transport of photons from source to detector as a means of improving radiation therapy by enhanced utilization of kV and MV x-ray imaging
FY 2019-20
Summary
Introduction: This research program seeks to develop new algorithms to remove contaminating x-ray scatter from diagnostic and therapeutic medical images obtained in modern radiation therapy. Current radiation treatment units use kilovoltage (KV) x-rays for anatomical imaging (ie. cone-beam computed tomography, CBCT) just prior to therapy delivery using a megavoltage (MV) x-ray beam. Therapy and diagnostic imaging applications on these units are currently at a rudimentary level.***Hypothesis: A hybrid scatter estimation algorithm for both MV and KV energy x-rays will improve the accuracy of image reconstruction and density conversion (CBCT) and also improve the accuracy of dose reconstruction (MV) providing increased sensitivity for error detection. ***Objectives: 1. Develop a hybrid scatter estimation algorithm combining a deterministic approach with a novel, fast Monte Carlo method. 2. Validate and optimize this algorithm using both MV and KV x-ray beams. 3. Combine interleaved KV and MV imaging allowing diagnostic imaging during therapy delivery.***Methods: Building on our previous experience, a hybrid algorithm will be developed to estimate x-ray scatter from patients for both KV and MV energy x-ray beams. A fast analytical solution will estimate singly-scattered x-rays, while a novel Monte Carlo approach treating each voxel as a scatter source will estimate multiply-scattered x-rays. The method will be validated on both MV therapeutic beams and KV (CBCT) diagnostic imaging beams and quantitatively evaluated in terms of reconstruction accuracy and improved contrast (CBCT), and patient reconstructed dose accuracy (MV) on a variety of geometric and anthropomorphic phantoms. Furthermore, an interleaved acquisition approach will be developed to concurrently obtain KV and MV image data during radiation treatment delivery through the use of XML control software, minimizing the impact of patient motion. Performance will be assessed through quantitative comparison of image quality results to standard sequential image acquisition.***Significance: This research program will provide significantly improved quality CBCT data on radiation treatment units (i.e. improved tumour visibility, accurate density conversions). For MV imaging, more accurate patient dose reconstructions will be provided, improving sensitivity in detecting delivery errors. Interleaved image acquisition will provide a more accurate representation of patient anatomy during treatment. Future research opportunities for real-time tumour tracking and adaptive radiation therapy will be created.***Conclusion: This research program builds on our experience developing scatter estimation algorithms and their applications to improve the accuracy of radiation treatments. Eventually these advances may be used throughout Canada and the world to improve quality of life for all patients treated with radiation.**
Program
Discovery Grants Program - Individual
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2015-05623
Name nom
Mccurdy, Boyd
Department département
Physics and Astronomy
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2015
Award amount
24000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Installment
inst:5 - 5
Partie
5
Nb partie
5
Application title
Modeling the transport of photons from source to detector as a means of improving radiation therapy by enhanced utilization of kV and MV x-ray imaging
Keyword
NSERC
Application summary
Introduction: This research program seeks to develop new algorithms to remove contaminating x-ray scatter from diagnostic and therapeutic medical images obtained in modern radiation therapy. Current radiation treatment units use kilovoltage (KV) x-rays for anatomical imaging (ie. cone-beam computed tomography, CBCT) just prior to therapy delivery using a megavoltage (MV) x-ray beam. Therapy and diagnostic imaging applications on these units are currently at a rudimentary level.***Hypothesis: A hybrid scatter estimation algorithm for both MV and KV energy x-rays will improve the accuracy of image reconstruction and density conversion (CBCT) and also improve the accuracy of dose reconstruction (MV) providing increased sensitivity for error detection. ***Objectives: 1. Develop a hybrid scatter estimation algorithm combining a deterministic approach with a novel, fast Monte Carlo method. 2. Validate and optimize this algorithm using both MV and KV x-ray beams. 3. Combine interleaved KV and MV imaging allowing diagnostic imaging during therapy delivery.***Methods: Building on our previous experience, a hybrid algorithm will be developed to estimate x-ray scatter from patients for both KV and MV energy x-ray beams. A fast analytical solution will estimate singly-scattered x-rays, while a novel Monte Carlo approach treating each voxel as a scatter source will estimate multiply-scattered x-rays. The method will be validated on both MV therapeutic beams and KV (CBCT) diagnostic imaging beams and quantitatively evaluated in terms of reconstruction accuracy and improved contrast (CBCT), and patient reconstructed dose accuracy (MV) on a variety of geometric and anthropomorphic phantoms. Furthermore, an interleaved acquisition approach will be developed to concurrently obtain KV and MV image data during radiation treatment delivery through the use of XML control software, minimizing the impact of patient motion. Performance will be assessed through quantitative comparison of image quality results to standard sequential image acquisition.***Significance: This research program will provide significantly improved quality CBCT data on radiation treatment units (i.e. improved tumour visibility, accurate density conversions). For MV imaging, more accurate patient dose reconstructions will be provided, improving sensitivity in detecting delivery errors. Interleaved image acquisition will provide a more accurate representation of patient anatomy during treatment. Future research opportunities for real-time tumour tracking and adaptive radiation therapy will be created.***Conclusion: This research program builds on our experience developing scatter estimation algorithms and their applications to improve the accuracy of radiation treatments. Eventually these advances may be used throughout Canada and the world to improve quality of life for all patients treated with radiation.**