Grant: Engage Grants Program
McMaster University
$24,748.00
On enhancing the performance of elbow thermosyphon heat pipes
FY 2015-16
Summary
Mersen Canada Inc., located in Mississauga, ON, is a global designer, manufacturer, and provider of thermal management solutions for high power electrical systems. These include proprietary long-finned heat sinks, liquid cooled systems and heat pipe systems. Mersen Canada is strongly committed to developing new two-phase heat pipe systems and, to that end, they recently enhanced and expanded their test facilities at Mississauga. This project focusses on improving the performance of elbow thermosyphon heat pipes that Mersen Canada currently manufactures for, and uses in a number of thermal management applications. In this system, heat generated by losses in electronic modules is transported from a heat spreader to large, near-horizontal extended fin surfaces that are cooled by ram air-flow or natural convection. Thermosyphons are
passive two phase heat transport devices; evaporating a working fluid in heated regions and condensing it in cooled regions, to transfer the heat with a small thermal resistance. The elbow thermosyphons considered here differ from most thermosyphons in that they are bent to pass along the heated surface to provide longer evaporator sections to meet the heat flux requirements. Mersen Canada is forced to deal with bent thermosyphons due to the packaging constraints of the application. The working fluid is water to meet environmental constraints. There is a need to improve the performance of the elbow thermosyphons to be competitive in markets with warmer climates, and to compete with more expensive cooling system designs, such as liquid cooling. Experiments will be performed to determine methods of enhancement that will include:
inclining the evaporator section, changing the interior surface to a wick structure, and doping the working fluid with nanoparticles. These have been shown to reduce the thermal resistance of straight thermosyphons. An improvement in the performance of elbow thermosyphons will lead to new opportunities and markets for Mersen, which a resultant increase in sales and larger manufacturing footprint in Ontario.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
487356-2015
Name nom
Ching, Chan
Department département
Mechanical Engineering
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
24748
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
On enhancing the performance of elbow thermosyphon heat pipes
Keyword
NSERC
Application summary
Mersen Canada Inc., located in Mississauga, ON, is a global designer, manufacturer, and provider of thermal management solutions for high power electrical systems. These include proprietary long-finned heat sinks, liquid cooled systems and heat pipe systems. Mersen Canada is strongly committed to developing new two-phase heat pipe systems and, to that end, they recently enhanced and expanded their test facilities at Mississauga. This project focusses on improving the performance of elbow thermosyphon heat pipes that Mersen Canada currently manufactures for, and uses in a number of thermal management applications. In this system, heat generated by losses in electronic modules is transported from a heat spreader to large, near-horizontal extended fin surfaces that are cooled by ram air-flow or natural convection. Thermosyphons are
passive two phase heat transport devices; evaporating a working fluid in heated regions and condensing it in cooled regions, to transfer the heat with a small thermal resistance. The elbow thermosyphons considered here differ from most thermosyphons in that they are bent to pass along the heated surface to provide longer evaporator sections to meet the heat flux requirements. Mersen Canada is forced to deal with bent thermosyphons due to the packaging constraints of the application. The working fluid is water to meet environmental constraints. There is a need to improve the performance of the elbow thermosyphons to be competitive in markets with warmer climates, and to compete with more expensive cooling system designs, such as liquid cooling. Experiments will be performed to determine methods of enhancement that will include:
inclining the evaporator section, changing the interior surface to a wick structure, and doping the working fluid with nanoparticles. These have been shown to reduce the thermal resistance of straight thermosyphons. An improvement in the performance of elbow thermosyphons will lead to new opportunities and markets for Mersen, which a resultant increase in sales and larger manufacturing footprint in Ontario.