Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Toronto

$25,000.00

Development of a Direct-to-Suite Ventilation System for Multi-Unit Residential Building Retrofits

FY 2019-20

Summary
Post-war multi-unit residential buildings are typically ventilated using a centralized make-up air unit (MAU), which is intended to positively pressurize the common building corridors and provide ventilation air to suites through door undercuts. Overcladding retrofits for these buildings are gaining popularity as they offer better thermal comfort and energy efficiency by improving building air tightness and insulation levels. However, as a result of these retrofits, the pressurized corridor ventilation strategy is becoming insufficient. The need for alternative ventilation strategies in these buildings is opening up a retrofit market which Nu-Air Ventilation Systems Inc. plans to capitalize on with a new low-profile, high-efficiency, heat/energy recovery ventilator (H/ERV).Through this research partnership, the H/ERV unit design will be optimized with respect to air flow rate requirements for different system layouts, unit dimensions including the height-to-width ratio, thermal efficiency compared to national standards and incentive program requirements, and hardware cost to ensure acceptability by a large market share. To determine the requirements for the design, computer simulations calibrated with field data will be used. These simulations will be based on a case study building in Ontario, representing Nu-Air's target archetype building.This process will leverage rarely collected interzonal air leakage data and air flow data derived from fan-pressurization and tracer gas testing to calibrate the airflow models. This unique approach will ensure a more realistic representation of these building types compared to existing models, to help develop the first H/ERV specifically designed for this retrofit application. This project will allow Nu-Air to bolster their H/ERV product line and give them a competitive advantage in the global marketplace, simultaneously strengthening the Canadian economy.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
541951-2019
Name nom
Touchie, Marianne
Department département
Civil & Mineral Engineering, Dept of
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Development of a Direct-to-Suite Ventilation System for Multi-Unit Residential Building Retrofits
Keyword
NSERC
Application summary
Post-war multi-unit residential buildings are typically ventilated using a centralized make-up air unit (MAU), which is intended to positively pressurize the common building corridors and provide ventilation air to suites through door undercuts. Overcladding retrofits for these buildings are gaining popularity as they offer better thermal comfort and energy efficiency by improving building air tightness and insulation levels. However, as a result of these retrofits, the pressurized corridor ventilation strategy is becoming insufficient. The need for alternative ventilation strategies in these buildings is opening up a retrofit market which Nu-Air Ventilation Systems Inc. plans to capitalize on with a new low-profile, high-efficiency, heat/energy recovery ventilator (H/ERV).Through this research partnership, the H/ERV unit design will be optimized with respect to air flow rate requirements for different system layouts, unit dimensions including the height-to-width ratio, thermal efficiency compared to national standards and incentive program requirements, and hardware cost to ensure acceptability by a large market share. To determine the requirements for the design, computer simulations calibrated with field data will be used. These simulations will be based on a case study building in Ontario, representing Nu-Air's target archetype building.This process will leverage rarely collected interzonal air leakage data and air flow data derived from fan-pressurization and tracer gas testing to calibrate the airflow models. This unique approach will ensure a more realistic representation of these building types compared to existing models, to help develop the first H/ERV specifically designed for this retrofit application. This project will allow Nu-Air to bolster their H/ERV product line and give them a competitive advantage in the global marketplace, simultaneously strengthening the Canadian economy.