Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Idea to Innovation

McMaster University

$125,000.00

Multiplexing confocal technology

FY 2015-16

Summary
Comparing to conventional wide-field imaging microscopes, confocal microscopy hold significant advantages in image contrast enhancement, 3D sectioning capabilities, and compatibility with specialized detectors. Despite of being more costly, complicated to operate, and slow image acquisition rate, over the past decade, confocal fluorescence microscope has emerged as an important scientific research tool as well as applications in drug discovery, clinical pathology, etc. For applications such as live cell imaging, slow acquisition speed is a key barrier to adaption of confocal microscopy. While wide-field microscopy is typically faster, multiplexed confocal schemes such as using a spinning foci array can significantly increase the image acquisition rate. The moving foci array in the spinning disc, however, prevents the use of specialized discrete photo detectors arrays. We have developed a suite of technologies to generate, scan, and measure 100-400 confocal foci simultaneously, while is compatible with stationary discrete detectors. Another key feature of the technique is that it can be retrofitted to a conventional wide-field fluorescence microscope. The basic operation principle has been validated on a benchtop set up on live cell imaging. In this NSERC Idea-to-Innovation project, we plan to build a fully integrated, single-box prototype instrument that is fully compatible with conventional wide-field fluorescence microscopes from all four major manufacturers (Zeiss, Nikon, Olympus, and Leica). We will also explore subsequent commercialization pathways for such technology. In the next 12 months we plan to i) integration all modules into a single box, ""manufacturing prototype"", ii) characterize its performance on living cell imaging on different brand of commercial fluorescence microscopes and comparing them to commercial spinning disc confocal systems, and iii) evaluate different discrete photodetector array technologies and identify pathways to integration. Successful completion of the proposed prototype development will significantly strengthen the developed technology and its potential for the next phase commercialization plans.
Program
Idea to Innovation
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
486815-2015
Name nom
Fang, Qiyin
Department département
Engineering Physics
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
125000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1201
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Life sciences (including biotechnology)
Area of application fr
Sciences de la vie (y compris biotechnologie)
Research subject code
2505
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Photon devices
Research subject fr
Dispositifs photoniques
Partie
1
Nb partie
1
Application title
Multiplexing confocal technology
Keyword
NSERC
Application summary
Comparing to conventional wide-field imaging microscopes, confocal microscopy hold significant advantages in image contrast enhancement, 3D sectioning capabilities, and compatibility with specialized detectors. Despite of being more costly, complicated to operate, and slow image acquisition rate, over the past decade, confocal fluorescence microscope has emerged as an important scientific research tool as well as applications in drug discovery, clinical pathology, etc. For applications such as live cell imaging, slow acquisition speed is a key barrier to adaption of confocal microscopy. While wide-field microscopy is typically faster, multiplexed confocal schemes such as using a spinning foci array can significantly increase the image acquisition rate. The moving foci array in the spinning disc, however, prevents the use of specialized discrete photo detectors arrays. We have developed a suite of technologies to generate, scan, and measure 100-400 confocal foci simultaneously, while is compatible with stationary discrete detectors. Another key feature of the technique is that it can be retrofitted to a conventional wide-field fluorescence microscope. The basic operation principle has been validated on a benchtop set up on live cell imaging. In this NSERC Idea-to-Innovation project, we plan to build a fully integrated, single-box prototype instrument that is fully compatible with conventional wide-field fluorescence microscopes from all four major manufacturers (Zeiss, Nikon, Olympus, and Leica). We will also explore subsequent commercialization pathways for such technology. In the next 12 months we plan to i) integration all modules into a single box, ""manufacturing prototype"", ii) characterize its performance on living cell imaging on different brand of commercial fluorescence microscopes and comparing them to commercial spinning disc confocal systems, and iii) evaluate different discrete photodetector array technologies and identify pathways to integration. Successful completion of the proposed prototype development will significantly strengthen the developed technology and its potential for the next phase commercialization plans.
McMaster University - $125,000 Grant (2015-16) | Canada Spends