Grant: Collaborative Research and Development Grants
University of British Columbia
$84,910.00
Design and assessment of frameless system for seismic applications
FY 2018-19
Summary
Frameless system is a solution for long-span low-rise steel structures that consists of engineered cold-formed steel corrugated panels, thus eliminating the need for additional seismic force resisting system. The corrugated panels (such as the wall, ceiling and roof elements) are fabricated off-site, shipped to site and assembled. This makes Frameless system one of the most efficient solutions for commercial and industrial constructions, where short erection time is required. With these advantages, Frameless system have gained steady market shares in Canada and worldwide. Frameless system is currently used for a variety of applications, such as industrial, recreational and commercial usages. Frameless system is a product of Behlen Industries, Canada's largest manufacturer of steel building systems. Behlen has over 40 years of history manufacturing steel building systems and investing heavily in engineering technology, fabrication concepts, structural improvements, and building quality. As a result, Frameless systems today are far better in terms of cost, strength, function, and aesthetics. Through these innovations, Behlen has moved the Frameless system to a higher level and help to position the long-term growth and greater acceptance in Canada and worldwide. However, there is a gap of knowledge to confirm the applicability of using Frameless system as a seismic force resisting system. Currently, the seismic design practice for the Frameless system uses a force-based approach, where Frameless system is designed as conventional construction. There are no registers of Frameless system in previous seismic events and no test data in terms of cyclic response. This research proposal is targeted to investigate the seismic performance of Frameless system. A robust methodology involving a thorough experimental and analytical program is proposed to be executed at the University of British Columbia (UBC) Structural Engineering Laboratory. In this research, the Frameless system will be systematically examined from the material level to cross section level, eventually from the element and system level. Once the experimental and analytical programs have been completed, detailed design methods for the Frameless system will be developed accordance with current Canadian codes. Hence, the Frameless system can be used as a pre-qualified seismic force resisting system in Canada. This will ensure a more robust, economical and reliable seismic force resisting system to be used in high seismic regions in Canada and worldwide.
Program
Collaborative Research and Development Grants
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
529848-2018
Name nom
Yang, Tony
Department département
Civil Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
84910
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Design and assessment of frameless system for seismic applications
Keyword
NSERC
Application summary
Frameless system is a solution for long-span low-rise steel structures that consists of engineered cold-formed steel corrugated panels, thus eliminating the need for additional seismic force resisting system. The corrugated panels (such as the wall, ceiling and roof elements) are fabricated off-site, shipped to site and assembled. This makes Frameless system one of the most efficient solutions for commercial and industrial constructions, where short erection time is required. With these advantages, Frameless system have gained steady market shares in Canada and worldwide. Frameless system is currently used for a variety of applications, such as industrial, recreational and commercial usages. Frameless system is a product of Behlen Industries, Canada's largest manufacturer of steel building systems. Behlen has over 40 years of history manufacturing steel building systems and investing heavily in engineering technology, fabrication concepts, structural improvements, and building quality. As a result, Frameless systems today are far better in terms of cost, strength, function, and aesthetics. Through these innovations, Behlen has moved the Frameless system to a higher level and help to position the long-term growth and greater acceptance in Canada and worldwide. However, there is a gap of knowledge to confirm the applicability of using Frameless system as a seismic force resisting system. Currently, the seismic design practice for the Frameless system uses a force-based approach, where Frameless system is designed as conventional construction. There are no registers of Frameless system in previous seismic events and no test data in terms of cyclic response. This research proposal is targeted to investigate the seismic performance of Frameless system. A robust methodology involving a thorough experimental and analytical program is proposed to be executed at the University of British Columbia (UBC) Structural Engineering Laboratory. In this research, the Frameless system will be systematically examined from the material level to cross section level, eventually from the element and system level. Once the experimental and analytical programs have been completed, detailed design methods for the Frameless system will be developed accordance with current Canadian codes. Hence, the Frameless system can be used as a pre-qualified seismic force resisting system in Canada. This will ensure a more robust, economical and reliable seismic force resisting system to be used in high seismic regions in Canada and worldwide.