Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Ottawa

$25,000.00

Development of a simplified procedure to predict wind loading on structures using the Computational Fluid Dynamic (CFD)

FY 2014-15

Summary
Structures must be able to withstand the external loads imposed by nature. Wind is one of the major forces responsible for the catastrophic failure of structures and loss of life. Therefore, accurate evaluation and prediction of wind loads and proper mitigations are very important in reducing the adverse effects of wind in the built environment. In addition to the mean and the background (due to turbulent fluctuations) loads on rigid buildings, flexible structures will be subjected to resonant wind loads as well. The primary source of the wind motion is the pressure fluctuations in the windward and leeward faces due to the fluctuation in the approach flow and its interaction with the building. Building codes and Standards usually provide loads along the wind direction for common shapes in open and suburban terrain category. Wind pressure on a structure is a functionof the characteristics of the wind, the geometry of the structure, and the geometry and proximity of the structure upwind. Because of the many uncertainties involved, the maximum wind loads experienced by a structure during its lifetime, may vary widely from those assumed in design. Thus, failure or non-failure of a structure in a wind storm can not necessarily be taken as an indication of the non-conservativeness, or conservativeness, of the wind loading standard. The commonly used standard in Canada is the National Building Code of Canada (NBCC, 2010). NBCC recommend dynamic analysis to be performed for certain structures of unusual geometry or tall. Standards such as NBCC are commonly used to predict the response of structures under wind loading. Both static and dynamic procedures can be used accordingly. However, wind tunnel testing can be used to design tall buildings for more complex structures. Wind tunnel tests data on buildings and structurescan be used to design a structure as well as to determine the flow fields induced around the structure. The computational fluid dynamic (CFD) numerical simulations is also a promising tool to predict the behavior of a structure under wind loading. The main purpose of this project is to predict the behaviour of structures using the CFD simulation and to develop a simplified procedure for the engineering profession.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
477436-2014
Name nom
Mohammadian, Abdolmajid
Department département
Civil Engineering
Organization id
28
Institution établissement
University of Ottawa
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1002
Area of application group en
Northern development
Area of application group fr
Développement du nord
Area of application en
Environment
Area of application fr
Environnement
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Development of a simplified procedure to predict wind loading on structures using the Computational Fluid Dynamic (CFD)
Keyword
NSERC
Application summary
Structures must be able to withstand the external loads imposed by nature. Wind is one of the major forces responsible for the catastrophic failure of structures and loss of life. Therefore, accurate evaluation and prediction of wind loads and proper mitigations are very important in reducing the adverse effects of wind in the built environment. In addition to the mean and the background (due to turbulent fluctuations) loads on rigid buildings, flexible structures will be subjected to resonant wind loads as well. The primary source of the wind motion is the pressure fluctuations in the windward and leeward faces due to the fluctuation in the approach flow and its interaction with the building. Building codes and Standards usually provide loads along the wind direction for common shapes in open and suburban terrain category. Wind pressure on a structure is a functionof the characteristics of the wind, the geometry of the structure, and the geometry and proximity of the structure upwind. Because of the many uncertainties involved, the maximum wind loads experienced by a structure during its lifetime, may vary widely from those assumed in design. Thus, failure or non-failure of a structure in a wind storm can not necessarily be taken as an indication of the non-conservativeness, or conservativeness, of the wind loading standard. The commonly used standard in Canada is the National Building Code of Canada (NBCC, 2010). NBCC recommend dynamic analysis to be performed for certain structures of unusual geometry or tall. Standards such as NBCC are commonly used to predict the response of structures under wind loading. Both static and dynamic procedures can be used accordingly. However, wind tunnel testing can be used to design tall buildings for more complex structures. Wind tunnel tests data on buildings and structurescan be used to design a structure as well as to determine the flow fields induced around the structure. The computational fluid dynamic (CFD) numerical simulations is also a promising tool to predict the behavior of a structure under wind loading. The main purpose of this project is to predict the behaviour of structures using the CFD simulation and to develop a simplified procedure for the engineering profession.