Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments - Category 1 (<$150,000)

Queen's University

$23,551.00

Microplate UV/VIS spectrophotometer

FY 2007-08

Summary
Funds are requested to purchase a Molecular Devices SpectraMax 190 Microplate UV/VIS Spectrophotometer, together with requisite software and computer system (needed for data acquisition & analysis), and a quartz microplate (needed for absorbance determinations in the UV range). This is required to replace to an unrepairable and obsolete Molecular Devices SpectraMax 250 plate reader that has been heavily used since its purchase in 1998, but became non-functional earlier this year. The SpectraMax 250 was discontinued in 1998, is no longer serviced, and its spare parts have not been available for the past 2 years. The microplate spectrophotometer is a highly versatile and essential research tool for my laboratory personnel. They use it on a daily basis for a wide variety of biochemical procedures, including high-throughput activity assays and kinetic studies of key enzymes of plant metabolism. The microplate reader has also been extensively used to perform end-point assays such as protein, nucleic acid, and phosphate determinations. Over the past 5 years we have integrated several powerful molecular biological and genomic tools into our research, which necessitates spectrophotometric quantification of DNA/RNA at 260 nm. The SpectraMax 190 has been significantly upgraded with additional features such as being fully tunable over a broad UV-VIS range (190-850 nm), as well as  a PathCheck Sensor which senses the depth of liquid in each well and normalizes absorbance values to a conventional 1 cm pathlength. The spectral scanning feature enables us to determine absorbance spectra for various compounds and purified enzymes. Molecular Devices's microplate analysis software (Softmax Pro) provides comprehensive instrument control and data reduction. My research group (currently 1 post-doc, 1 res. assoc., 4 graduate & 1 undergraduate student) have experienced significant disruptions to their work since our SpectraMax 250 plate reader became non-functional. If funded, the SpectraMax 190 Spectrophotometer would be a huge asset for my ongoing research program and HQP training.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
359858-2008
Name nom
Plaxton, William
Department département
Biology
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2008
Award amount
23551
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
3
Committee name en
Plant Biology & Food Science
Committee name fr
Biol vég/sc alimentaire
Area of application code
103
Area of application group en
Agriculture and primary food production
Area of application group fr
Agriculture et produits alimentaires primaires
Area of application en
Plant production and plant primary products
Area of application fr
Production végétale et produits végétaux primaires
Research subject code
5404
Research subject group en
Biochemistry
Research subject group fr
Biochimie
Research subject en
Enzymes
Research subject fr
Enzymes
Partie
1
Nb partie
1
Application title
Microplate UV/VIS spectrophotometer
Keyword
NA
Application summary
Funds are requested to purchase a Molecular Devices SpectraMax 190 Microplate UV/VIS Spectrophotometer, together with requisite software and computer system (needed for data acquisition & analysis), and a quartz microplate (needed for absorbance determinations in the UV range). This is required to replace to an unrepairable and obsolete Molecular Devices SpectraMax 250 plate reader that has been heavily used since its purchase in 1998, but became non-functional earlier this year. The SpectraMax 250 was discontinued in 1998, is no longer serviced, and its spare parts have not been available for the past 2 years. The microplate spectrophotometer is a highly versatile and essential research tool for my laboratory personnel. They use it on a daily basis for a wide variety of biochemical procedures, including high-throughput activity assays and kinetic studies of key enzymes of plant metabolism. The microplate reader has also been extensively used to perform end-point assays such as protein, nucleic acid, and phosphate determinations. Over the past 5 years we have integrated several powerful molecular biological and genomic tools into our research, which necessitates spectrophotometric quantification of DNA/RNA at 260 nm. The SpectraMax 190 has been significantly upgraded with additional features such as being fully tunable over a broad UV-VIS range (190-850 nm), as well as  a PathCheck Sensor which senses the depth of liquid in each well and normalizes absorbance values to a conventional 1 cm pathlength. The spectral scanning feature enables us to determine absorbance spectra for various compounds and purified enzymes. Molecular Devices's microplate analysis software (Softmax Pro) provides comprehensive instrument control and data reduction. My research group (currently 1 post-doc, 1 res. assoc., 4 graduate & 1 undergraduate student) have experienced significant disruptions to their work since our SpectraMax 250 plate reader became non-functional. If funded, the SpectraMax 190 Spectrophotometer would be a huge asset for my ongoing research program and HQP training.