Grant: Discovery Grants Program - Individual
Université de Sherbrooke
$15,000.00
Design and characterization of a new microCT/radiotherapy system
FY 2012-13
Summary
Medical imaging is used to diagnose diverse types of diseases, for patient follow-up, and for pharmacological studies. Even computed tomography (CT) utilizes X-ray radiations, it is however the most widespread due to its compact size, the ease of its operation, its simple maintenance and its non-confinement. Meanwhile, CT has a limited functionality with respect to other medical imaging modalities based on radioisotopes. CT provides quantitative 3D static or dynamic images, in a rapid and non-invasive fashion with a very high spatial resolution. With the injection of contrast agents, CT can provide dynamic morphological information in tissue and organs. In the present research project, we propose the design of a microCT for small animals, rapid (30 images/sec) and at high spatial resolution (100 microns). The X-ray source (SX), a microfocus, provides a variable energy for imaging different tissues and a focal point size of 13 to 20 microns performing very high spatial resolution. The detecting system is formed by a flat panel detector (PD) of 24 cm x 12 cm accommodating a rat of 400 g. Furthermore, in the proposed architecture, the animal bed can be displaced at three positions and the PD at two positions for image magnification when measuring small organs in rats and mice. The whole system SX and PD rotates at 360o around the animal to obtain a 3D volume images. The other original characteristic of our setup is that we want to treat tumors implanted in small animals with this same X-ray source and by taking advantage of the precision on the tumor localization with our scanner. Therefore, the tumor is also precisely localized depending on angle views in addition to the displacement of the animal with respect to SX to better target the tumor. With the utilization of usual contrast agents, or those to be developed with our collaborators, we will work on the quantification of the dynamic measures to calculate the physiological parameters in diverse organs and tissues, and for pharmacological studies.
Program
Discovery Grants Program - Individual
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
238542-2011
Name nom
Bentourkia, MHamed
Department département
Médecine nucléaire et radiobiologie
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2011
Award amount
15000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
2
Nb partie
5
Application title
Design and characterization of a new microCT/radiotherapy system
Keyword
NSERC
Application summary
Medical imaging is used to diagnose diverse types of diseases, for patient follow-up, and for pharmacological studies. Even computed tomography (CT) utilizes X-ray radiations, it is however the most widespread due to its compact size, the ease of its operation, its simple maintenance and its non-confinement. Meanwhile, CT has a limited functionality with respect to other medical imaging modalities based on radioisotopes. CT provides quantitative 3D static or dynamic images, in a rapid and non-invasive fashion with a very high spatial resolution. With the injection of contrast agents, CT can provide dynamic morphological information in tissue and organs. In the present research project, we propose the design of a microCT for small animals, rapid (30 images/sec) and at high spatial resolution (100 microns). The X-ray source (SX), a microfocus, provides a variable energy for imaging different tissues and a focal point size of 13 to 20 microns performing very high spatial resolution. The detecting system is formed by a flat panel detector (PD) of 24 cm x 12 cm accommodating a rat of 400 g. Furthermore, in the proposed architecture, the animal bed can be displaced at three positions and the PD at two positions for image magnification when measuring small organs in rats and mice. The whole system SX and PD rotates at 360o around the animal to obtain a 3D volume images. The other original characteristic of our setup is that we want to treat tumors implanted in small animals with this same X-ray source and by taking advantage of the precision on the tumor localization with our scanner. Therefore, the tumor is also precisely localized depending on angle views in addition to the displacement of the animal with respect to SX to better target the tumor. With the utilization of usual contrast agents, or those to be developed with our collaborators, we will work on the quantification of the dynamic measures to calculate the physiological parameters in diverse organs and tissues, and for pharmacological studies.