Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

École de technologie supérieure

$25,000.00

Design of orthopedic implants made of porous metallic materials using additive manufacturing technologies

FY 2019-20

Summary
Long-term survivorship of orthopedic implants remains a challenge as patients are becoming younger and more active. One factor compromising the longevity of the implant is bone resorption believed to be due to stress shielding. Bone is a living tissue and reacts to its mechanical stimuli. When bone is removed to be replaced by an artificial implant, a redistribution of the stresses within the bone occurs. This stress shielding phenomenon occurs because of the large difference in rigidity between the metallic implant and the surrounding bone. The bone is thus stress shielded, consequently the bone is resorbed and its density decreased, eventually leading to failure of the arthroplasty. New materials are needed to mimic the natural bone to reduce the stress shielding phenomenon.****Nowadays, additive manufacturing technologies make possible complex, well-controlled porous materials such as metals with high porosity (50-80%) having material properties tailored to the desired need. Such new materials can be used to design implants with reduced stiffness to diminish the stress shielding. Furthermore, they allow for good osteointegration within the porosity (cell growth through the implant for appropriate stability). Infinity of structures at the mesoscale can be fabricated, thus infinity of mechanical properties can be designed. The implant can be functionally graded by having regions of high porosity and other regions with less porosity or no porosity. Finally, customized implants adapted to each patient can be manufactured.****The aim of this research program is to design and model new porous metallic materials obtained using additive manufacturing technologies for orthopedic applications. Numerical modeling is widely used to predict the mechanical behavior of implants of total joint replacements. Accurate prediction can be obtained because of the homogeneity of the solid material. However, for highly porous metallic materials, the mechanical behavior is not predicted accurately since the structure at the mesoscale is made of slender struts and voids. The nominal dimensions at the mesoscale are of the order of hundreds of microns. As an example for an implant, strut diameters are approximately 500 microns and pores 800 microns. The discrepancy between nominal and actual (manufactured) dimensions becomes important for highly porous materials. As a result, the mechanical behavior predicted with finite element models differ importantly from experimental data. Finite element analysis is essential to study the overall (at the macroscale) and local (at the mesoscale) mechanical behavior of porous materials to design implants, before mechanical testing and pre-clinical testing. This research program will develop numerical tools to predict the porous metallic materials using experiments to validate the numerical model.******
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2017-05958
Name nom
Nuño, Natalia
Department département
Génie de la production automatisée
Organization id
53
Institution établissement
École de technologie supérieure
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2017
Award amount
25000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Installment
inst:3 - 5
Partie
3
Nb partie
5
Application title
Design of orthopedic implants made of porous metallic materials using additive manufacturing technologies
Keyword
NSERC
Application summary
Long-term survivorship of orthopedic implants remains a challenge as patients are becoming younger and more active. One factor compromising the longevity of the implant is bone resorption believed to be due to stress shielding. Bone is a living tissue and reacts to its mechanical stimuli. When bone is removed to be replaced by an artificial implant, a redistribution of the stresses within the bone occurs. This stress shielding phenomenon occurs because of the large difference in rigidity between the metallic implant and the surrounding bone. The bone is thus stress shielded, consequently the bone is resorbed and its density decreased, eventually leading to failure of the arthroplasty. New materials are needed to mimic the natural bone to reduce the stress shielding phenomenon.****Nowadays, additive manufacturing technologies make possible complex, well-controlled porous materials such as metals with high porosity (50-80%) having material properties tailored to the desired need. Such new materials can be used to design implants with reduced stiffness to diminish the stress shielding. Furthermore, they allow for good osteointegration within the porosity (cell growth through the implant for appropriate stability). Infinity of structures at the mesoscale can be fabricated, thus infinity of mechanical properties can be designed. The implant can be functionally graded by having regions of high porosity and other regions with less porosity or no porosity. Finally, customized implants adapted to each patient can be manufactured.****The aim of this research program is to design and model new porous metallic materials obtained using additive manufacturing technologies for orthopedic applications. Numerical modeling is widely used to predict the mechanical behavior of implants of total joint replacements. Accurate prediction can be obtained because of the homogeneity of the solid material. However, for highly porous metallic materials, the mechanical behavior is not predicted accurately since the structure at the mesoscale is made of slender struts and voids. The nominal dimensions at the mesoscale are of the order of hundreds of microns. As an example for an implant, strut diameters are approximately 500 microns and pores 800 microns. The discrepancy between nominal and actual (manufactured) dimensions becomes important for highly porous materials. As a result, the mechanical behavior predicted with finite element models differ importantly from experimental data. Finite element analysis is essential to study the overall (at the macroscale) and local (at the mesoscale) mechanical behavior of porous materials to design implants, before mechanical testing and pre-clinical testing. This research program will develop numerical tools to predict the porous metallic materials using experiments to validate the numerical model.******
École de technologie supérieure - $25,000 Grant (2019… | Canada Spends