Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Alberta

$48,000.00

Technical development of sodium magnetic resonance imaging of the human knee

FY 2010-11

Summary
Engineering advances of hardware and software over the last 25 years have made magnetic resonance imaging (MRI) indispensable for the diagnosis and improved understanding of many human diseases and disorders. Routine clinical MRI measures signal from the hydrogen nucleus (i.e. proton, 1H) of water and it is unique differences in the water properties of tissue that yields image contrast. However, with the appropriate engineering, MRI can acquire signal from a different nucleus, namely the naturally abundant sodium (23Na) ion within the body. Sodium is linked directly to proper cell function, and may provide evidence of tissue injury despite normal appearance on conventional MRI. Sodium MRI is inherently very challenging because of low sensitivity due to sodium's low concentration in tissue and complicated physics responses. Therefore, sodium MRI is a non-standard imaging technique not available on most clinical 1.5T (i.e. strength of the magnetic field) MRI scanners because of the lack of appropriate electronics and specialized imaging pulse sequences. Imaging is more sensitive if the MRI scanner has a very strong magnetic field. This proposal will take advantage of a very strong ""triple strength"" MRI scanner (4.7T) located at the University of Alberta. The goal of this technical grant is to develop the hardware and software for sodium MRI of cartilage in the knee as sodium concentration is directly linked with cartilage degradation in osteoarthritis, a debilitating condition which affects millions of Canadians. On the other hand, current standard MRI of water is not specific to cartilage damage. Imaging the sodium ion in the knee will require us to design, build in-house, and test new MRI electronic components (i.e. radiofrequency coils). Computer simulations will be used to predict the parameters that will yield the best signal-to-noise ratio given a desired image resolution and scan duration. Once we engineer, optimize, and test our novel MRI scans on healthy people, the noninvasive assessment of sodium in cartilage could be applied in the future to people with osteoarthritis of the knee.
Program
Discovery Grants Program - Individual
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
293226-2009
Name nom
Beaulieu, Christian
Department département
Biomedical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2009
Award amount
48000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1079
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et de l'informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
5
Application title
Technical development of sodium magnetic resonance imaging of the human knee
Keyword
NSERC
Application summary
Engineering advances of hardware and software over the last 25 years have made magnetic resonance imaging (MRI) indispensable for the diagnosis and improved understanding of many human diseases and disorders. Routine clinical MRI measures signal from the hydrogen nucleus (i.e. proton, 1H) of water and it is unique differences in the water properties of tissue that yields image contrast. However, with the appropriate engineering, MRI can acquire signal from a different nucleus, namely the naturally abundant sodium (23Na) ion within the body. Sodium is linked directly to proper cell function, and may provide evidence of tissue injury despite normal appearance on conventional MRI. Sodium MRI is inherently very challenging because of low sensitivity due to sodium's low concentration in tissue and complicated physics responses. Therefore, sodium MRI is a non-standard imaging technique not available on most clinical 1.5T (i.e. strength of the magnetic field) MRI scanners because of the lack of appropriate electronics and specialized imaging pulse sequences. Imaging is more sensitive if the MRI scanner has a very strong magnetic field. This proposal will take advantage of a very strong ""triple strength"" MRI scanner (4.7T) located at the University of Alberta. The goal of this technical grant is to develop the hardware and software for sodium MRI of cartilage in the knee as sodium concentration is directly linked with cartilage degradation in osteoarthritis, a debilitating condition which affects millions of Canadians. On the other hand, current standard MRI of water is not specific to cartilage damage. Imaging the sodium ion in the knee will require us to design, build in-house, and test new MRI electronic components (i.e. radiofrequency coils). Computer simulations will be used to predict the parameters that will yield the best signal-to-noise ratio given a desired image resolution and scan duration. Once we engineer, optimize, and test our novel MRI scans on healthy people, the noninvasive assessment of sodium in cartilage could be applied in the future to people with osteoarthritis of the knee.