Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of British Columbia

$25,000.00

Performance-based design guideline for strengthening I-joists with web holes and flange notches

FY 2012-13

Summary
I-joist is an engineered wood product that has more strength compared to a regular timber beam of similar size and weight. During wood frame construction web holes and flange notches are made for the passage of service ducts, plumbing and wiring. Eventually, the ultimate capacity and stiffness of the I-joist section get significantly reduced by the web opening and/or notch flanges. This phenomenon is more critical in those cases where the presence of opening is close to the support since the shear is critical at that location, which may lead to premature failure. Here, several specimens will be tested with square and circular holes under two point loading condition in order to capture the accurate failure pattern of the I-joists. The holes will be cut in the support and the mid span region. Similar types of specimens will be repaired by steel angles and steel or wood stiffeners and tested under the same loading condition. Steel angles/stiffeners will be used at the openings along one or both side of the joist on top and bottom of the flange. The leg of the angle will be glued with both web and flange of the I-joists. It is expected that the load carrying capacities of the repaired I-joists will be significantly improved. The angles and stiffeners are expected to prevent the premature failure in opening locations and the failure in ultimate load will be more ductile in nature. The tested specimens will be simulated and validated by a 3D finite element (FE) model. All range of specimens commonly used in construction will be modeled in FE to evaluate all possible failure mechanisms. Finally, a simplified design guideline will be developed to predict the capacity and failure mechanism of the specimens. In addition, a detailed guideline will be also developed to repair the damaged section due to the presence of opening. The amount of repairing/retrofitting will be calculated based on the experimental investigations and FE model analysis. This study will provide some cost-effective retrofit solutions for repairing deficient I-joists with openings. The significance of this research is paramount as it directly contributes to the safety and security to Canadian building infrastructure.
Program
Engage Grants Program
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
441777-2012
Name nom
Alam, Shahria
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1101
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural loads and safety
Research subject fr
Charges structurales et sécurité
Partie
1
Nb partie
1
Application title
Performance-based design guideline for strengthening I-joists with web holes and flange notches
Keyword
NSERC
Application summary
I-joist is an engineered wood product that has more strength compared to a regular timber beam of similar size and weight. During wood frame construction web holes and flange notches are made for the passage of service ducts, plumbing and wiring. Eventually, the ultimate capacity and stiffness of the I-joist section get significantly reduced by the web opening and/or notch flanges. This phenomenon is more critical in those cases where the presence of opening is close to the support since the shear is critical at that location, which may lead to premature failure. Here, several specimens will be tested with square and circular holes under two point loading condition in order to capture the accurate failure pattern of the I-joists. The holes will be cut in the support and the mid span region. Similar types of specimens will be repaired by steel angles and steel or wood stiffeners and tested under the same loading condition. Steel angles/stiffeners will be used at the openings along one or both side of the joist on top and bottom of the flange. The leg of the angle will be glued with both web and flange of the I-joists. It is expected that the load carrying capacities of the repaired I-joists will be significantly improved. The angles and stiffeners are expected to prevent the premature failure in opening locations and the failure in ultimate load will be more ductile in nature. The tested specimens will be simulated and validated by a 3D finite element (FE) model. All range of specimens commonly used in construction will be modeled in FE to evaluate all possible failure mechanisms. Finally, a simplified design guideline will be developed to predict the capacity and failure mechanism of the specimens. In addition, a detailed guideline will be also developed to repair the damaged section due to the presence of opening. The amount of repairing/retrofitting will be calculated based on the experimental investigations and FE model analysis. This study will provide some cost-effective retrofit solutions for repairing deficient I-joists with openings. The significance of this research is paramount as it directly contributes to the safety and security to Canadian building infrastructure.