Grant: Engage Grants Program
Concordia University
$25,000.00
Development of MEMS-based thermal sensors for gas sensing and vacuum pressure measurements**
FY 2018-19
Summary
Gas sensors helps to prevent the spread of hazardous gases and play important roles in places with the risk of potentially harmful substances specifically in industrial processes and manufacturing plants. Chemical gas sensors are based on chemical reaction between gas and sensing materials, resulting in change of conductivity of the detector materials. Recently, First Sensor Corp, a company in Montreal fabricating various sensor devices, has developed a MEMS-based thermal sensor for pressure and flow measurements of gases with several industrial applications in particular in medical and pharmaceutical areas. Further commercialization of the sensor requires improvement of its function. Due to the low selectivity and limited resolution of the device, the sensor cannot be used in analyzing gas mixtures containing more than two components or in applications where small concentration of certain gases should be detected. On the other hand, the device is very sensitive to changes in moisture, temperature. To provide opportunities to further commercialize the device, extensive improvement in design and characteristics of the device are required. Development of signal processing algorithms and advanced operating modes for the thermal gas sensor including operation at different overheating temperatures, compensation of temperature drift, drift of internal parameters of the sensing element and noise reduction routines will improve performance of the device. Development of an improved thermal gas sensors requires advanced engineering expertise and advanced experimental setup with possibility to adjust accurately various gas mixtures and control ambient pressure from 1 atmosphere to less than 1mTorr. The characterization of the sensor and design of its electronics circuitry will be performed in the laboratories of Micro/Nano devices in ECE department at Concordia University with collaboration of engineers and expertise of First Sensor Corp. *
Program
Engage Grants Program
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
537470-2018
Name nom
KAHRIZI, MOJTABA
Department département
Electrical and Computer Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
400
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Environment
Area of application fr
Environnement
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
1
Nb partie
1
Application title
Development of MEMS-based thermal sensors for gas sensing and vacuum pressure measurements**
Keyword
NSERC
Application summary
Gas sensors helps to prevent the spread of hazardous gases and play important roles in places with the risk of potentially harmful substances specifically in industrial processes and manufacturing plants. Chemical gas sensors are based on chemical reaction between gas and sensing materials, resulting in change of conductivity of the detector materials. Recently, First Sensor Corp, a company in Montreal fabricating various sensor devices, has developed a MEMS-based thermal sensor for pressure and flow measurements of gases with several industrial applications in particular in medical and pharmaceutical areas. Further commercialization of the sensor requires improvement of its function. Due to the low selectivity and limited resolution of the device, the sensor cannot be used in analyzing gas mixtures containing more than two components or in applications where small concentration of certain gases should be detected. On the other hand, the device is very sensitive to changes in moisture, temperature. To provide opportunities to further commercialize the device, extensive improvement in design and characteristics of the device are required. Development of signal processing algorithms and advanced operating modes for the thermal gas sensor including operation at different overheating temperatures, compensation of temperature drift, drift of internal parameters of the sensing element and noise reduction routines will improve performance of the device. Development of an improved thermal gas sensors requires advanced engineering expertise and advanced experimental setup with possibility to adjust accurately various gas mixtures and control ambient pressure from 1 atmosphere to less than 1mTorr. The characterization of the sensor and design of its electronics circuitry will be performed in the laboratories of Micro/Nano devices in ECE department at Concordia University with collaboration of engineers and expertise of First Sensor Corp. *