Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Waterloo

$25,000.00

Development of field emission based x-ray for non destructive testing (NDT) applications

FY 2016-17

Summary
The proposed project is focused on the development of a novel Stationary X-ray Tomosynthesis System(SXTS) and a Multi-Beam X-ray Source (MBXS) for Non-Destructive Testing (NDT). The proposed SXTSconsists of a novel X-ray source, which can irradiate the object from different angles without mechanicalmotion, a flat panel X-ray detector, a control system, and an image reconstruction workstation. The proposedMBXS is the core components of the system, which consists of an array of high density miniaturized X-raytubes that can generate multiple X-ray beams. SXTS presents a new X-ray 3D imaging NDT technology. TheSXTS technology utilizes electrically controlled multiple X-ray sources to replace the traditional single X-raysource and the gantry structure, therefore, the system can achieve a very high scanning speed and easy tosynchronize with a high speed conveyor. The core component to realize SXTS is the proposed MBXStechnology, which is based on our patented field emission (FE) X-ray cathode design.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
505454-2016
Name nom
Yeow, Tzewei
Department département
Systems Design Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
703
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Aerospace
Area of application fr
Aérospatial
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
Development of field emission based x-ray for non destructive testing (NDT) applications
Keyword
NSERC
Application summary
The proposed project is focused on the development of a novel Stationary X-ray Tomosynthesis System(SXTS) and a Multi-Beam X-ray Source (MBXS) for Non-Destructive Testing (NDT). The proposed SXTSconsists of a novel X-ray source, which can irradiate the object from different angles without mechanicalmotion, a flat panel X-ray detector, a control system, and an image reconstruction workstation. The proposedMBXS is the core components of the system, which consists of an array of high density miniaturized X-raytubes that can generate multiple X-ray beams. SXTS presents a new X-ray 3D imaging NDT technology. TheSXTS technology utilizes electrically controlled multiple X-ray sources to replace the traditional single X-raysource and the gantry structure, therefore, the system can achieve a very high scanning speed and easy tosynchronize with a high speed conveyor. The core component to realize SXTS is the proposed MBXStechnology, which is based on our patented field emission (FE) X-ray cathode design.