Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments

Simon Fraser University

$61,943.00

Contact angle goniometer for characterizing dynamic wetting and superwettability

FY 2024-25

Summary
The contact angle of liquids is an essential parameter for surface characterization in materials science. It conveys crucial information beyond the wettability and surface energy of a material, as it is dictated by the chemical composition and micro/nano-structural morphology. In the past 20 years, contact angle goniometers have evolved from a basic setup of a light source and a microscope to a complex, intelligent ensemble. A modern goniometer includes light sources of various wavelengths, a high-resolution and high-speed camera, a contact-free liquid jetting system, and an automated sample stage, which is operated in conjunction with advanced software for image capturing and data processing. This proposal is to support the acquisition of a new, cutting-edge replacement for our outdated, unfunctional contact angle goniometer acquired 20 years ago. The proposed instrument not only offers high-accuracy liquid contact angle measurements, but also integrates essential features such as an automated contact-free liquid dispensing unit for measuring super-wettability and an automated tilting stage for studying dynamic wetting. The new benchtop goniometer will elevate the throughput and precision of surface/material characterization and will be essential for ongoing research projects within multiple groups in the Department of Chemistry, 4D Labs, and the School of Engineering Science at Simon Fraser University. It will pave the way for new research projects involving the creation of novel superhydrophobic or icephobic materials and the fabrication of flexible, switchable sensors or other biomedical devices.
Program
Research Tools and Instruments
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RTI-2025-00581
Name nom
Yu, Hua-Zhong (Hogan)
Department département
Department of Chemistry
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2025
Award amount
61943
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1604
Committee name en
Chemistry (RTI)
Committee name fr
Chimie (OIR)
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
3402
Research subject group en
Physical chemistry
Research subject group fr
Chimie physique
Research subject en
Surface and interfacial chemistry
Research subject fr
Chimie des surfaces et des interfaces
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Contact angle goniometer for characterizing dynamic wetting and superwettability
Keywords
contact angle goniometer; wettability; surface tension; superhydrophobicity; icephobicity; surface modification; dynamic wetting; biochip fabrication
Application summary
The contact angle of liquids is an essential parameter for surface characterization in materials science. It conveys crucial information beyond the wettability and surface energy of a material, as it is dictated by the chemical composition and micro/nano-structural morphology. In the past 20 years, contact angle goniometers have evolved from a basic setup of a light source and a microscope to a complex, intelligent ensemble. A modern goniometer includes light sources of various wavelengths, a high-resolution and high-speed camera, a contact-free liquid jetting system, and an automated sample stage, which is operated in conjunction with advanced software for image capturing and data processing. This proposal is to support the acquisition of a new, cutting-edge replacement for our outdated, unfunctional contact angle goniometer acquired 20 years ago. The proposed instrument not only offers high-accuracy liquid contact angle measurements, but also integrates essential features such as an automated contact-free liquid dispensing unit for measuring super-wettability and an automated tilting stage for studying dynamic wetting. The new benchtop goniometer will elevate the throughput and precision of surface/material characterization and will be essential for ongoing research projects within multiple groups in the Department of Chemistry, 4D Labs, and the School of Engineering Science at Simon Fraser University. It will pave the way for new research projects involving the creation of novel superhydrophobic or icephobic materials and the fabrication of flexible, switchable sensors or other biomedical devices.
Simon Fraser University - $61,943 Grant (2024-25) | Canada Spends