Grant: Engage Grants Program

McGill University

$25,000.00

Flexible Dry Electrodes for Acquiring Electroencephalogram Signals

FY 2017-18

Summary
Due to drawbacks of wet electrodes such as the need for conductive gel and scalp preparation, Avertus Inc.uses two different kinds of dry electrodes in the current electroencephalogram (EEG) recording headsets.Electrodes for hairy locations are equipped with straight macroscale gold plated retractable pins, whereaselectrodes for non-hairy locations are a conductive textile over conductive foam. Pin electrode becomeuncomfortable with time for people with thin hair because the springs in the pin electrodes create pressure.They are an injury hazard under impact condition and the retractable nature of the pin electrodes makes thedevice bulky. Moreover, using two different kinds of electrodes causes the impedance mismatch issue. In thisproject, we will develop a low cost flexible conductive material and fabricate electrodes from it. A conductivepolymer composite (CPC) consisting of polydimethylsiloxane (PDMS) and metal nanoparticles (Nps) withconductivity >1000 S/m will be prepared as electrode material. Electrodes for hairy and non-hairy locationswill be produced from the CPC in different shapes for scalps with different contours. To characterize theperformance for each electrode structure the contact impedance between the dry skin and electrode will bemeasured. The fabricated electrodes will be integrated with the Avertus's prototype headset and EEG signalswill be recorded. Effect of long-term usage, sanitization and multiple usage on the electrode performance willbe evaluated. The proposed flexible conductive dry electrodes will miniaturize the headset and allow it to beworn comfortably and safely for long time. The use of same material for hairy and non-hairy locationelectrodes will remove the impedance mismatch issue in the current headset.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
521295-2017
Name nom
Bhadra, Sharmistha
Department département
Electrical and Computer Engineering
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2515
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electronic materials and components
Research subject fr
Matériels et composants électroniques
Partie
1
Nb partie
1
Application title
Flexible Dry Electrodes for Acquiring Electroencephalogram Signals
Keyword
NSERC
Application summary
Due to drawbacks of wet electrodes such as the need for conductive gel and scalp preparation, Avertus Inc.uses two different kinds of dry electrodes in the current electroencephalogram (EEG) recording headsets.Electrodes for hairy locations are equipped with straight macroscale gold plated retractable pins, whereaselectrodes for non-hairy locations are a conductive textile over conductive foam. Pin electrode becomeuncomfortable with time for people with thin hair because the springs in the pin electrodes create pressure.They are an injury hazard under impact condition and the retractable nature of the pin electrodes makes thedevice bulky. Moreover, using two different kinds of electrodes causes the impedance mismatch issue. In thisproject, we will develop a low cost flexible conductive material and fabricate electrodes from it. A conductivepolymer composite (CPC) consisting of polydimethylsiloxane (PDMS) and metal nanoparticles (Nps) withconductivity >1000 S/m will be prepared as electrode material. Electrodes for hairy and non-hairy locationswill be produced from the CPC in different shapes for scalps with different contours. To characterize theperformance for each electrode structure the contact impedance between the dry skin and electrode will bemeasured. The fabricated electrodes will be integrated with the Avertus's prototype headset and EEG signalswill be recorded. Effect of long-term usage, sanitization and multiple usage on the electrode performance willbe evaluated. The proposed flexible conductive dry electrodes will miniaturize the headset and allow it to beworn comfortably and safely for long time. The use of same material for hairy and non-hairy locationelectrodes will remove the impedance mismatch issue in the current headset.