Grant: Vanier Canada Graduate Scholarships - Doctoral
University of Waterloo
$50,000.00
Chirped-Pulse Interferometry - Enhanced Optical Imaging using Chirped Laser Pulses
FY 2012-13
Summary
Biomedical imaging requires high resolution to see the fine features of a sample and fast acquisition speed because living systems tend to move around. At the same time it must use low power to avoid harming the specimen. Optical coherence tomography (OCT) is a powerful technique which uses optical interference for non-invasive high resolution 3D imaging in biological samples. Interference is the pattern of light and dark regions created when two beams of light are superposed.
The resolution of OCT is determined by the length over which the light used will interfere. Unfortunately, dispersion, the frequency dependent velocity of light, hurts the imaging resolution by broadening interference features and lowering interference contrast. A technique called quantum-OCT (QOCT) is immune to dispersion but requires quantum mechanically entangled photon pairs. Entanglement is a property of quantum mechanical systems involving two or more particles that cannot be described separately. The need for entanglement drastically reduces the number of photons available for imaging, making QOCT too slow to be practical.
Chirped-pulse interferometry (CPI) is also immune to dispersion. A pulse is a short burst of laser light, lasting as little as a few millionths of a billionth of a second. A chirped pulse is one where the frequency, or colour, of the light changes from red to blue from one end of the pulse to the other. CPI has better resolution than OCT, automatic dispersion cancellation, and 10,000,000 times the signal strength of QOCT.
CPI has been demonstrated in the lab, but with insufficient resolution and power levels too high to use with living samples. In the proposed project we will build a prototype setup using CPI for dispersion-cancelled 3D imaging of a biological sample, with a resolution comparable to conventional OCT systems. This will be a major advance in biomedical imaging.
Program
Vanier Canada Graduate Scholarships - Doctoral
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
405659-2011
Name nom
Schreiter, Kurt
Department département
Physics and Astronomy
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2011
Award amount
50000
Program id
VCGS
Program name en
Vanier Canada Graduate Scholarships - Doctoral
Program name fr
Bourses d'études supérieures du Canada Vanier - Doctorat
Group en
Training programs
Group fr
Programmes de bourse
Committee code
1082
Committee name en
Vanier Selection Committee
Committee name fr
Comité de sélection Vanier
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
3110
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Optics (see also photon devices2505)
Research subject fr
Optique (voir aussi dispositifs photoniques, 2505)
Partie
0
Application title
Chirped-Pulse Interferometry - Enhanced Optical Imaging using Chirped Laser Pulses
Keyword
NSERC
Application summary
Biomedical imaging requires high resolution to see the fine features of a sample and fast acquisition speed because living systems tend to move around. At the same time it must use low power to avoid harming the specimen. Optical coherence tomography (OCT) is a powerful technique which uses optical interference for non-invasive high resolution 3D imaging in biological samples. Interference is the pattern of light and dark regions created when two beams of light are superposed.
The resolution of OCT is determined by the length over which the light used will interfere. Unfortunately, dispersion, the frequency dependent velocity of light, hurts the imaging resolution by broadening interference features and lowering interference contrast. A technique called quantum-OCT (QOCT) is immune to dispersion but requires quantum mechanically entangled photon pairs. Entanglement is a property of quantum mechanical systems involving two or more particles that cannot be described separately. The need for entanglement drastically reduces the number of photons available for imaging, making QOCT too slow to be practical.
Chirped-pulse interferometry (CPI) is also immune to dispersion. A pulse is a short burst of laser light, lasting as little as a few millionths of a billionth of a second. A chirped pulse is one where the frequency, or colour, of the light changes from red to blue from one end of the pulse to the other. CPI has better resolution than OCT, automatic dispersion cancellation, and 10,000,000 times the signal strength of QOCT.
CPI has been demonstrated in the lab, but with insufficient resolution and power levels too high to use with living samples. In the proposed project we will build a prototype setup using CPI for dispersion-cancelled 3D imaging of a biological sample, with a resolution comparable to conventional OCT systems. This will be a major advance in biomedical imaging.