Grant: Research Tools and Instruments - Category 1 (<$150,000)
Université de Montréal
$24,956.00
Upgrading of J-810 spectropolarimeter with fluorescence measurement
FY 2007-08
Summary
Fluorescence, the emission of light, often occurs after molecules are submitted to a ray of light. The characteristics of this emitted fluorescent light is very sensitive to the shape and environment of the molecules being studied. Therefore, fluorescent spectroscopy is a tool of choice to study a wide variety of aspects regarding the functions of molecules. One example of such studies is the characterization of the shape of molecules and how these shapes are modified when their environment changes (increase of temperature or in salt concentration, for instance). This information gives an idea of the resilience of the shape and thus of the stability of the molecule. Another example is the study of the interaction of two molecules. By monitoring the changes in fluorescence when two molecules interact, the effects of the interaction on the shape of the molecules, as well as the strength of the association, can be inferred. Additionally, all the parameters of the environment that affect the interaction can be investigated. If no or little fluorescence is naturally emitted by a molecule of interest, there are thousands of artificial fluorescent probes that can be chemically coupled to it. The grafted fluorescent probe will give an accurate picture of its environment and thus yield the same information as above, most of the times with a clearer spatial resolution because the location of the probe is precisely known.Fluorescence is measured by a fluorometer. A spectropolarimeter can also measure a parameter that is strongly affected by the molecules structure and environment: the polarization of transmitted light. Combining polarization and fluorescence greatly enhances the range of information on the structure and interaction of molecules. In order to benefit from this synergy, our proposal is to add fluorescence measurement abilities to our spectropolarimeter. The fundamental knowledge gained by studies with this equipment will be instrumental in our studies on the molecular mechanisms of bacteria and how they cause diseases. In turn, our studies enable us to develop strategies to fight infections.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
359334-2008
Name nom
Mourez, Michael
Department département
Pathologie et microbiologie
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2008
Award amount
24956
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
32
Committee name en
Cell Biology
Committee name fr
Biologie cellulaire
Area of application code
102
Area of application group en
Agriculture and primary food production
Area of application group fr
Agriculture et produits alimentaires primaires
Area of application en
Animal management (animal diseases, breeding)
Area of application fr
Gestion des animaux (maladies animales, reproduction)
Research subject code
5201
Research subject group en
Microbiology
Research subject group fr
Microbiologie
Research subject en
Bacteriology
Research subject fr
Bactériologie
Partie
1
Nb partie
1
Application title
Upgrading of J-810 spectropolarimeter with fluorescence measurement
Keyword
NA
Application summary
Fluorescence, the emission of light, often occurs after molecules are submitted to a ray of light. The characteristics of this emitted fluorescent light is very sensitive to the shape and environment of the molecules being studied. Therefore, fluorescent spectroscopy is a tool of choice to study a wide variety of aspects regarding the functions of molecules. One example of such studies is the characterization of the shape of molecules and how these shapes are modified when their environment changes (increase of temperature or in salt concentration, for instance). This information gives an idea of the resilience of the shape and thus of the stability of the molecule. Another example is the study of the interaction of two molecules. By monitoring the changes in fluorescence when two molecules interact, the effects of the interaction on the shape of the molecules, as well as the strength of the association, can be inferred. Additionally, all the parameters of the environment that affect the interaction can be investigated. If no or little fluorescence is naturally emitted by a molecule of interest, there are thousands of artificial fluorescent probes that can be chemically coupled to it. The grafted fluorescent probe will give an accurate picture of its environment and thus yield the same information as above, most of the times with a clearer spatial resolution because the location of the probe is precisely known.Fluorescence is measured by a fluorometer. A spectropolarimeter can also measure a parameter that is strongly affected by the molecules structure and environment: the polarization of transmitted light. Combining polarization and fluorescence greatly enhances the range of information on the structure and interaction of molecules. In order to benefit from this synergy, our proposal is to add fluorescence measurement abilities to our spectropolarimeter. The fundamental knowledge gained by studies with this equipment will be instrumental in our studies on the molecular mechanisms of bacteria and how they cause diseases. In turn, our studies enable us to develop strategies to fight infections.