Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Queen's University

$26,000.00

Improved friction and wear performance in polymeric components of orthopaedic bearings.

FY 2015-16

Summary
Nearly 25,000 Canadians and 600,000 worldwide are implanted with an artificial knee each year. These devices are most often designed using specialized components made of metal (cobalt chrome) and plastic (ultrahigh molecular weight polyethylene). They are the treatment of choice for severe degenerative joint disease, and they are now being implanted in active patients, some as young as 45. As a result, there is an increased need to improve their durability, particularly with respect to wear in the plastic component. While there have been improvements in the design of polyethylene for use in hips, this has not been the case for highly stressed joints such as the knee. This project examines a novel way of treating the plastic material surface to reduce wear. It is thought that small indentations, or dimples, in the polyethylene surface will entrain joint fluid that will help lubricate the joint and also reduce the stress on the plastic itself. With reduced stress, reduced plastic wear should result. It is reasoned that human cartilage morphology, which has naturally occurring dimples less than 40 micrometers in diameter and 15 micrometers deep, could be used as a model for the surface texture. This geometry will be reproduced on polyethylene surfaces using specialized processing facilities at Queen's and tested to determine if this can reduce friction and wear in laboratory specimens. If successful, the texturing process will be evaluated on artificial joints in a wear simulator that reproduces loads and motion that occur in real life. The aim is to reduce the need to replace worn out artificial knees by improving their durability beyond the 15 years currently expected and provide a growing number of aging adults with a lifetime of activity well past what is now possible.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
5223-2013
Name nom
Bryant, Tim
Department département
Mechanical and Materials Engineering
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2013
Award amount
26000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
3
Nb partie
5
Application title
Improved friction and wear performance in polymeric components of orthopaedic bearings.
Keyword
NSERC
Application summary
Nearly 25,000 Canadians and 600,000 worldwide are implanted with an artificial knee each year. These devices are most often designed using specialized components made of metal (cobalt chrome) and plastic (ultrahigh molecular weight polyethylene). They are the treatment of choice for severe degenerative joint disease, and they are now being implanted in active patients, some as young as 45. As a result, there is an increased need to improve their durability, particularly with respect to wear in the plastic component. While there have been improvements in the design of polyethylene for use in hips, this has not been the case for highly stressed joints such as the knee. This project examines a novel way of treating the plastic material surface to reduce wear. It is thought that small indentations, or dimples, in the polyethylene surface will entrain joint fluid that will help lubricate the joint and also reduce the stress on the plastic itself. With reduced stress, reduced plastic wear should result. It is reasoned that human cartilage morphology, which has naturally occurring dimples less than 40 micrometers in diameter and 15 micrometers deep, could be used as a model for the surface texture. This geometry will be reproduced on polyethylene surfaces using specialized processing facilities at Queen's and tested to determine if this can reduce friction and wear in laboratory specimens. If successful, the texturing process will be evaluated on artificial joints in a wear simulator that reproduces loads and motion that occur in real life. The aim is to reduce the need to replace worn out artificial knees by improving their durability beyond the 15 years currently expected and provide a growing number of aging adults with a lifetime of activity well past what is now possible.